DNA LoBind® is available as a variety of formats including the 96-well microplate for superior recovery
Deep well Eppendorf LoBind® plate with blue border
![Deep well Eppendorf LoBind® plate with blue border Deep well Eppendorf LoBind® plate with blue border](/product-media/img/global/0030501241_main_01/Eppendorf_Sample-Preparation_DWP-96x1000ul-DNA-LoBind_blue_3_product.jpg?imwidth=920)
Available in deep well format for the ultimate sample recovery
Barcoded Eppendorf LoBind® plate in deep well format
![Barcoded Eppendorf LoBind® plate in deep well format Barcoded Eppendorf LoBind® plate in deep well format](/product-media/img/global/DWP_96x500_white/Eppendorf_Sample-Preparation_DWP-96x500ul-DNA-LoBind_white_barcode_product.jpg?imwidth=920)
DNA LoBind® plates come with the option to barcode to facilitate automated liquid handling
epT.I.P.S.® L elongated pipette tips in use to fill a Deepwell plate
![epT.I.P.S.® L elongated pipette tips in use to fill a Deepwell plate Sample being pipetted from elongated ep T.I.P.S.® to Eppendorf LoBind® deepwell plate](/product-media/img/global/42365/Eppendorf_Liquid-Handling_ep-TIPS_elongated_product.jpg?imwidth=920)
Eppendorf Protein LoBind® deepwell plates are compatible with elongated ep T.I.P.S.®
Eppendorf LoBind® - How it works
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/zcRu1XEfoDU/hqdefault.jpg)
-
Barcode Option Available
Product Information
Our innovative DNA LoBind technology reduces sample-to-surface binding to ensure maximum nucleic acid recovery and offer the ideal solution for sample preparations and long-term storage.
Customized barcoding is available for select versions of this product. Please visit the detail page for eligible products to access the Barcode Wizard and start designing your label.
![Logo of "assembled with 100% renewable power" at Eppendorf](/product-media/img/global/1041745/Eppendorf_Sustainability_Assembled-renewable-power-logo_RGB_logo.jpg?imwidth=160)
You will find additional download material at the bottom of this page
Products (10)
10 Products
Price
$ 455.00
|
Price
$ 504.00
|
Price
$ 492.00
|
Price
$ 1,369.00
|
Price
$ 455.00
|
Price
$ 1,226.00
|
Price
$ 181.00
|
Price
$ 183.00
|
Price
$ 627.00
|
Price
$ 607.00
|
Show more Products
Added to Your Cart
Product Information
Applications
Features
Maximize recovery of nucleic acids with DNA LoBind® Plates! A combination of special manufacturing technologies and selected polypropylene batches ensure nearly 100 % recovery of DNA/RNA molecules-without surface coating to eliminate the risk of sample contamination. This makes Eppendorf LoBind Plates ideal for applications where sample recovery is key - such as the preparation of long-term storage nucleic acids in forensic, microarrays and NGS applications.
![Eppendorf LoBind® in deep well and microtube format](/product-media/img/global/119116/Eppendorf_Sample-Preparation_DWP-96x1000ul-Safe-Lock-Tubes.jpg?imwidth=920)
![Eppendorf LoBind® in deep well and microtube format](/product-media/img/global/119116/Eppendorf_Sample-Preparation_DWP-96x1000ul-Safe-Lock-Tubes.jpg?imwidth=540)
High-quality Eppendorf DNA LoBind® products
Available in a variety of formats, to help you recover nucleic acids, including tube, microplate and deepwell plate to meet the different application needs for various sample volumes and throughput.
![Eppendorf LoBind® in deep well and microtube format](/product-media/img/global/119116/Eppendorf_Sample-Preparation_DWP-96x1000ul-Safe-Lock-Tubes.jpg?imwidth=920)
![Eppendorf LoBind® in deep well and microtube format](/product-media/img/global/119116/Eppendorf_Sample-Preparation_DWP-96x1000ul-Safe-Lock-Tubes.jpg?imwidth=540)
![Bar chart depicting DNA recovery rate (%) in Eppendorf LoBind® Tubes compared to competitor tubes](/product-media/img/global/6825/Eppendorf_Sample-Preparation_DNA-recovery-rate_diagram.jpg?imwidth=920)
![Bar chart depicting DNA recovery rate (%) in Eppendorf LoBind® Tubes compared to competitor tubes](/product-media/img/global/6825/Eppendorf_Sample-Preparation_DNA-recovery-rate_diagram.jpg?imwidth=540)
Superior DNA recovery rate
Eppendorf DNA LoBind® Tubes recover significantly more DNA than competitor tubes. DNA (0.2 ng/µL DNA fragment (130 bp, 32P labelled) in 2.5 M NaCl/TE buffer) was incubated at various conditions before being quantified to assess sample recovery. The Eppendorf DNA LoBind Tubes revealed up to 99 % sample recovery independent of the tested incubation temperature or time.
![Bar chart depicting DNA recovery rate (%) in Eppendorf LoBind® Tubes compared to competitor tubes](/product-media/img/global/6825/Eppendorf_Sample-Preparation_DNA-recovery-rate_diagram.jpg?imwidth=920)
![Bar chart depicting DNA recovery rate (%) in Eppendorf LoBind® Tubes compared to competitor tubes](/product-media/img/global/6825/Eppendorf_Sample-Preparation_DNA-recovery-rate_diagram.jpg?imwidth=540)
![Experiment conditions for real-time PCR analysis of DNA stored in competitor low bind tubes versus Eppendorf LoBind® Tubes](/product-media/img/global/14873/Eppendorf_Sample-Preparation_DNA-LoBind-tubes_illustration.jpg?imwidth=920)
![Experiment conditions for real-time PCR analysis of DNA stored in competitor low bind tubes versus Eppendorf LoBind® Tubes](/product-media/img/global/14873/Eppendorf_Sample-Preparation_DNA-LoBind-tubes_illustration.jpg?imwidth=540)
Get consistency in quantification
Eppendorf LoBind® Tubes offer greater recovery potential when compared to a low-retention competitor. An assessment of Eppendorf LoBind tube consistency in the preparation and storage of standards for real-time PCR absolute quantifications showed that the low adsorption of DNA to LoBind tubes improved the quality of standard curves and DNA quantification in assayed samples.
Image: Preparation of DNA standards: Genomic DNA stock solution was serially diluted 10–fold in competitor low retention tubes or Eppendorf DNA LoBind® Tubes. 22 µL aliquots of each dilution were stored for 24 hours at –80 °C before analysis by real-time PCR. Samples stored in Eppendorf LoBind® Tubes had a greater PCR efficiency when compared to the competitor. See Application Note 226 for more details.
![Experiment conditions for real-time PCR analysis of DNA stored in competitor low bind tubes versus Eppendorf LoBind® Tubes](/product-media/img/global/14873/Eppendorf_Sample-Preparation_DNA-LoBind-tubes_illustration.jpg?imwidth=920)
![Experiment conditions for real-time PCR analysis of DNA stored in competitor low bind tubes versus Eppendorf LoBind® Tubes](/product-media/img/global/14873/Eppendorf_Sample-Preparation_DNA-LoBind-tubes_illustration.jpg?imwidth=540)
Read More
Read Less
- Preparation or storage of DNA and RNA samples
- Forensic trace analysis
- Preparing dilution series in quantitative qPCR
- Sample preparation in next-generation sequencing
- Creation of genomic or oligonucleotide libraries
- Eppendorf LoBind material ensures optimized sample recovery for improved assay results
- Free of surface coating (e.g. silicone) to minimize the risk of sample interference
- Lot-certified PCR clean purity grade: free of human DNA, DNase, RNase and PCR inhibitors
- Available in tube, microplate, and deepwell plate formats for easy-up scaling
- High-contrast Unique OptiTrack® matrix: up to 30 % faster sample identification and fewer pipetting errors
- RecoverMax® well design: optimized well geometry for minimal remaining/dead volume and excellent mixing properties
- Raised well rims and a smooth surface ensure reliable sealing