Eppendorf Reference® 2 - Single-Button Pipette
On/Off switch to deactivate spring-loaded tip cones on Eppendorf Reference 2 multi-channel lower part
epT.I.P.S.® macro volume tips facilitate easy reach to the bottom of e.g. 15 mL centrifugation tubes or flasks
How to Pipette in 5 Simple Steps
Videos not loading, because cookies have been rejected. Change your
The unique single-button operation of the Eppendorf Reference® 2 (Interview with Product Manager)
Videos not loading, because cookies have been rejected. Change your
The premium design of the Eppendorf Reference® 2 (Interview with Product Designer)
Videos not loading, because cookies have been rejected. Change your
The outstanding robustness of the Eppendorf Reference® 2
Videos not loading, because cookies have been rejected. Change your
How the Eppendorf Reference® 2 looks from the inside
Videos not loading, because cookies have been rejected. Change your
The simple adjustment of the Eppendorf Reference® 2
Videos not loading, because cookies have been rejected. Change your
How to Fill Microplates Faster
Videos not loading, because cookies have been rejected. Change your
Multi-Channel Pipette Tip Attachment
Videos not loading, because cookies have been rejected. Change your
How to Take Care of Your Pipette
Videos not loading, because cookies have been rejected. Change your
Userguide : Pipette calibration
Videos not loading, because cookies have been rejected. Change your
Product Information
Choose the Eppendorf Reference 2 mechanical pipette with ergonomic single-button operation and benefit from its high precision and accuracy with reduced operating efforts. Its smooth surface and full autoclavability guarantee efficient decontamination - making it the ideal companion when working under sterile conditions. Available as a single-channel pipette in fixed or variable volume, and as 8- and 12-channel pipettes - all with time-saving single-button operation. Once you have experienced this unique operating philosophy you will not want to change back!Eppendorf Reference® 2 One-Button Pipette
You will find additional download material at the bottom of this page
Single Devices (34)
Sets & Bundles (3)
Services (27)
Accessories (16)
Spare Parts (48)
34 Single Devices
|
|
|
|
|
|
|
|
|
|
Show more Products
Product Information
Technical Data
Applications
Features
A premium pipette that delivers extraordinary precision and accuracy
The Eppendorf Reference 2 mechanical air-cushion pipette with outstanding precision and accuracy is extremely reliable and robust, allowing for a long service life. With its unique single-button operation, the Reference 2 provides fast and ergonomic handling with reduced operating efforts and active aerosol reduction. The clear haptic feedback helps to avoid accidental tip ejection. Don’t compromise on quality and reproducibility – choose the Eppendorf Reference 2 to confidently pipette precious samples accurately and improve your results.
The sturdy handle manufactured with stainless steel protects the pipette from impact and in combination with spring-loaded bumpers, the Reference 2 pipette is likely to stay within calibration even if it takes a fall. These high levels of security make the Reference 2 your ideal companion in applications requiring extremely high levels of accuracy.
Fast and ergonomic single-button operation
With the precise Eppendorf Reference 2 pipette, you can benefit from reduced strain thanks to lower operating forces for aspiration, dispensing and tip ejection. Users can also experience faster operation times as there is no need to move your thumb from side to side to eject tips, meaning you can move quickly through pipetting taks. And as tips are ejected immediately following dispensing, you can benefit from a reduced aerosol contamination of the pipette.
User-friendly temporary adjustment option
It is important to make sure you adjust your pipette according to sample type. The Reference 2 mechanical pipette allows you to do this easily without disturbing factory settings. A temporary and simple adjustment allows for an easy alteration of your Reference 2 to perform accurate pipetting of different liquids. Recommended settings are provided in the manual and you can easily and quickly reset to the manufacturer settings.
The ideal lab companion in sterile work environments
The Reference 2 pipette can easily be taken apart, is fully autoclavable and features a smooth housing being made in one pour. This offers advantages for any researcher concerned about bacterial contamination. With its low-adhesive surface and a minimum of cavities, grooves and sliding parts, the Reference 2 is easy to decontaminate and particularly suitable for use in class A/B cleanrooms and other sterile environments.
You have the choice: we offer a variety of single- and multi-channel options
Not all experiments are based on the same working conditions. Depending on the vessel type, you can choose from single-channel Reference 2 pipettes that are ideal for working with tubes and flasks, and multi-channel Reference 2 pipettes better suited for plates.
• Tubes & flasks: Single-channel choices, available as variable or fixed-volume pipettes
• 96- and 24-well plates: 8- and 12-channel pipette choices with option to deactivate the spring-loaded tip cones.
Fatigue-free and ergonomic pipetting
With it's unique single-button operation, the Eppendorf Reference 2 pipette features an innovative and highly ergonomic operation concept that was designed in line with the Eppendorf PhysioCare Concept® to minimize hand and arm strain. As most other Eppendorf pipettes, the Reference 2 premium pipette is of course equipped with the spring-loaded tip cone and SoftEject technologies from Eppendorf.
Spring-loaded tip cones allow for reliable tip fit and effortless attachment
Eppendorf pipettes with spring-loaded tip cone save you time and energy. With haptic feedback, all it takes is one gentle push-down for easy tip attachment. The spring limits the attachment forces and at the same time guarantees a reproducible and safe tip fit. This clever design provides increased user-to-user reproducibility and more consistent results between different lab members. All micropipettes from Eppendorf up to 1,000 µL (except Move It® 300 µL models) are equipped with the spring-loaded tip cone feature. In all Reference 2 multi-channel pipettes, the springs can easily be deactivated with an "On/Off" switch on the pipette lower part.
SoftEject technology reduces tip ejection forces by 50 %
All non-adjustable multi-channel pipettes from Eppendorf use the innovative SoftEject technology to ensure that during each single tip ejection stroke, the outside tips eject before the inside tips. This is not noticeable to the user but reduces tip ejection forces by 50 %. You just lightly press the ejection button once and the tips are automatically ejected in succession.
Read More
Read Less
Specifications | Eppendorf Reference® 2 - 4924000010 | Eppendorf Reference® 2 - 4924000029 | Eppendorf Reference® 2 - 4926000018 | Eppendorf Reference® 2 - 4926000026 | Eppendorf Reference® 2 - 4924000037 | Eppendorf Reference® 2 - 4924000045 | Eppendorf Reference® 2 - 4924000053 | Eppendorf Reference® 2 - 4926000034 | Eppendorf Reference® 2 - 4926000042 | Eppendorf Reference® 2 - 4924000061 | Eppendorf Reference® 2 - 4924000070 | Eppendorf Reference® 2 - 4926000050 | Eppendorf Reference® 2 - 4926000069 | Eppendorf Reference® 2 - 4924000088 | Eppendorf Reference® 2 - 4924000096 | Eppendorf Reference® 2 - 4924000100 | Eppendorf Reference® 2 - 4924000118 | Eppendorf Reference® 2 - 4925000014 | Eppendorf Reference® 2 - 4925000022 | Eppendorf Reference® 2 - 4925000030 | Eppendorf Reference® 2 - 4925000049 | Eppendorf Reference® 2 - 4925000057 | Eppendorf Reference® 2 - 4925000065 | Eppendorf Reference® 2 - 4925000073 | Eppendorf Reference® 2 - 4925000081 | Eppendorf Reference® 2 - 4925000090 | Eppendorf Reference® 2 - 4925000103 | Eppendorf Reference® 2 - 4925000111 | Eppendorf Reference® 2 - 4925000120 | Eppendorf Reference® 2 - 4925000138 | Eppendorf Reference® 2 - 4925000146 | Eppendorf Reference® 2 - 4925000154 | Eppendorf Reference® 2 - 4925000162 | Eppendorf Reference® 2 - 4925000170 |
---|
Product type | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes |
Pipetting type | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system |
Number of channels | 1-channel | 1-channel | 8-channel | 12-channel | 1-channel | 1-channel | 1-channel | 8-channel | 12-channel | 1-channel | 1-channel | 8-channel | 12-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel |
Volume range | 0.1 – 2.5 µL | 0.5 – 10 µL | 0.5 – 10 µL | 0.5 – 10 µL | 2 – 20 µL | 2 – 20 µL | 10 – 100 µL | 10 – 100 µL | 10 – 100 µL | 20 – 200 µL | 30 – 300 µL | 30 – 300 µL | 30 – 300 µL | 100 – 1,000 µL | 0.25 – 2.5 mL | 0.5 – 5 mL | 1 – 10 mL | 1 µL | 2 µL | 5 µL | 10 µL | 10 µL | 20 µL | 20 µL | 25 µL | 50 µL | 100 µL | 200 µL | 200 µL | 250 µL | 500 µL | 1,000 µL | 2 mL | 2.5 mL |
Color code | dark gray | medium gray | medium gray | medium gray | light gray | yellow | yellow | yellow | yellow | yellow | orange | orange | orange | blue | red | violet | turquoise | dark gray | dark gray | medium gray | medium gray | yellow | light gray | yellow | yellow | yellow | yellow | yellow | blue | blue | blue | blue | red | red |
Volume increment | 0.002 µL | 0.01 µL | 0.01 µL | 0.01 µL | 0.02 µL | 0.02 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.2 µL | 0.2 µL | 0.2 µL | 0.2 µL | 1 µL | 0.002 mL | 0.005 mL | 0.01 mL | − | − | − | − | − | − | − | − | − | − | − | − | − | − | − | − | − |
Operating mode | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical |
Spring-loaded tip cone | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | no | no | no | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | no | no |
Random measurement error |
0.1 µL: ± 12%; ± 0.012 µL 0.25 µL: ± 6%; ± 0.015 µL 1.25 µL: ± 1.5%; ± 0.01875 µL 2.5 µL: ± 0.7%; ± 0.0175 µL |
0.5 µL: ± 5%; ± 0.025 µL 1 µL: ± 1.8%; ± 0.018 µL 5 µL: ± 0.8%; ± 0.04 µL 10 µL: ± 0.4%; ± 0.04 µL |
0.5 µL: ± 8%; ± 0.04 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 2%; ± 0.1 µL 10 µL: ± 1%; ± 0.1 µL |
0.5 µL: ± 8%; ± 0.04 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 2%; ± 0.1 µL 10 µL: ± 1%; ± 0.1 µL |
1 µL: ± 3%; ± 0.03 µL 2 µL: ± 1.5%; ± 0.03 µL 20 µL: ± 0.6%; ± 0.06 µL 20 µL: ± 0.3%; ± 0.06 µL |
1 µL: ± 3%; ± 0.03 µL 2 µL: ± 1.5%; ± 0.03 µL 20 µL: ± 0.6%; ± 0.06 µL 20 µL: ± 0.3%; ± 0.06 µL |
5 µL: ± 2%; ± 0.1 µL 10 µL: ± 0.7%; ± 0.7 µL 50 µL: ± 0.3%; ± 0.015 µL 100 µL: ± 0.2%; ± 0.02 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.3%; ± 0.3 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.3%; ± 0.3 µL |
10 µL: ± 1.4%; ± 0.14 µL 20 µL: ± 0.7%; ± 0.14 µL 100 µL: ± 0.3%; ± 0.03 µL 200 µL: ± 0.2%; ± 0.4 µL |
15 µL: ± 1.4%; ± 0.21 µL 30 µL: ± 0.7%; ± 0.21 µL 150 µL: ± 0.3%; ± 0.45 µL 300 µL: ± 0.2%; ± 0.6 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.3%; ± 0.9 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.3%; ± 0.9 µL |
50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 0.6%; ± 0.6 µL 500 µL: ± 0.2%; ± 1 µL 1.000 µL: ± 0.2%; ± 2 µL |
250 µL: ± 1.2%; ± 3 µL 500 µL: ± 0.3%; ± 1.5 µL 1250 µL: ± 0.2%; ± 2.5 µL 2500 µL: ± 0.2%; ± 5 µL |
250 µL: ± 1.2%; ± 3 µL 500 µL: ± 0.6%; ± 3 µL 2500 µL: ± 0.25%; ± 6.25 µL 5.000 µL: ± 0.15%; ± 7.5 µL |
500 µL: ± 1.2%; ± 6 µL 1.000 µL: ± 0.6%; ± 6 µL 5.000 µL: ± 0.2%; ± 10 µL 10.000 µL: ± 0.15%; ± 15 µL |
1 µL: ± 1.8%; ± 0.018 µL | 2 µL: ± 1.2%; ± 0.024 µL | 5 µL: ± 0.6%; ± 0.03 µL | 10 µL: ± 0.5%; ± 0.05 µL | 10 µL: ± 0.6%; ± 0.06 µL | 20 µL: ± 0.3%; ± 0.06 µL | 20 µL: ± 0.3%; ± 0.06 µL | 25 µL: ± 0.3%; ± 0.075 µL | 50 µL: ± 0.3%; ± 0.15 µL | 100 µL: ± 0.2%; ± 0.2 µL | 200 µL: ± 0.2%; ± 0.4 µL | 200 µL: ± 0.2%; ± 0.4 µL | 250 µL: ± 0.2%; ± 0.5 µL | 500 µL: ± 0.2%; ± 1 µL | 1.000 µL: ± 0.2%; ± 2 µL | 2.000 µL: ± 0.2%; ± 4 µL | 2.500 µL: ± 0.2%; ± 5 µL |
Systematic measurement error |
0.1 µL: ± 48%; ± 0.048 µL 0.25 µL: ± 12%; ± 0.03 µL 1.25 µL: ± 2.5%; ± 0.031 µL 2.5 µL: ± 1.4%; ± 0.035 µL |
0.5 µL: ± 8%; ± 0.04 µL 1 µL: ± 2.5%; ± 0.025 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 1%; ± 0.1 µL |
0.5 µL: ± 12%; ± 0.06 µL 1 µL: ± 8%; ± 0.08 µL 5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL |
0.5 µL: ± 12%; ± 0.06 µL 1 µL: ± 8%; ± 0.08 µL 5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL |
1 µL: ± 10%; ± 0.1 µL 2 µL: ± 3%; ± 0.06 µL 20 µL: ± 1%; ± 0.1 µL 20 µL: ± 0.8%; ± 0.16 µL |
1 µL: ± 10%; ± 0.1 µL 2 µL: ± 5%; ± 0.1 µL 20 µL: ± 1.2%; ± 0.12 µL 20 µL: ± 1%; ± 0.2 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
10 µL: ± 5%; ± 0.5 µL 20 µL: ± 2.5%; ± 0.5 µL 100 µL: ± 1%; ± 1 µL 200 µL: ± 0.6%; ± 1.2 µL |
15 µL: ± 5%; ± 0.75 µL 30 µL: ± 2.5%; ± 0.75 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 3%; ± 0.9 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 3%; ± 0.9 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
50 µL: ± 6%; ± 3 µL 100 µL: ± 3%; ± 3 µL 500 µL: ± 1%; ± 5 µL 1.000 µL: ± 0.6%; ± 6 µL |
250 µL: ± 4.8%; ± 1.2 µL 500 µL: ± 1.5%; ± 7.5 µL 1250 µL: ± 0.8%; ± 10 µL 2500 µL: ± 0.6%; ± 15 µL |
250 µL: ± 4.8%; ± 12 µL 500 µL: ± 2.4%; ± 12 µL 2500 µL: ± 1.2%; ± 30 µL 5.000 µL: ± 0.6%; ± 30 µL |
500 µL: ± 6%; ± 30 µL 1.000 µL: ± 3%; ± 30 µL 5.000 µL: ± 0.8%; ± 40 µL 10.000 µL: ± 0.6%; ± 60 µL |
1 µL: ± 2.5%; ± 0.025 µL | 2 µL: ± 2%; ± 0.04 µL | 5 µL: ± 1.2%; ± 0.06 µL | 10 µL: ± 1%; ± 0.1 µL | 10 µL: ± 1.2%; ± 0.12 µL | 20 µL: ± 0.8%; ± 0.16 µL | 20 µL: ± 1%; ± 0.2 µL | 25 µL: ± 1%; ± 0.25 µL | 50 µL: ± 0.7%; ± 0.35 µL | 100 µL: ± 0.6%; ± 0.6 µL | 200 µL: ± 0.6%; ± 1.2 µL | 200 µL: ± 0.6%; ± 1.2 µL | 250 µL: ± 0.6%; ± 1.5 µL | 500 µL: ± 0.6%; ± 3 µL | 1.000 µL: ± 0.6%; ± 6 µL | 2.000 µL: ± 0.6%; ± 12 µL | 2.500 µL: ± 0.6%; ± 15 µL |
Autoclavable | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Consumables | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® |
Open system (third party consumables) | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Delivery content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Filter sleeve, Filter cartridges (x10), Pipette wrench | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Filter sleeve, Filter cartridges (x10), Pipette wrench | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Filter sleeve, Filter cartridges (x10), Pipette wrench | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment seal for temporary adjustment, Adjustment seal for factory adjustment (x2), Grease for pipettes, Locking ring (to prevent spring action) |
- Forward pipetting
- Reverse pipetting
- Removal of supernatants
- Sample mixing
- Phase extraction
- Filling of plates, gels, and reaction vessels
- Mechanical air-cushion pipette with outstanding precision and accuracy - operated with just one button for volume selection, pipetting and tip ejection
- With its innovative one-button operation, the Reference 2 allows fast and ergonomic handling with reduced operating efforts and active aerosol reduction. A clear haptic feedback helps to avoid accidental tip ejection
- 4-digit display with magnifying window for quick and secure volume setting and identification (clearly visible from every angle), incl. volume lock
- Spring-loaded tip cones improve user-to-user reproducibility and ergonomics by lowering the tip attachment force
- The unique smooth surface and full autoclavability guarantee efficient decontamination - making it the ideal companion when working under sterile conditions
- A temporary adjustment allows for an easy adjustment of your Reference 2 for the most accurate pipetting of different liquids or in changing external conditions without the need for a full calibration
- Available as single-channel pipette in fixed or variable volume as well as 8- and 12-channel pipette
- The Reference 2 multi-channel variants offer high flexibility incl. a spring-loaded tip cone which can be switched on/off optionally