BD | BDT
BD | BDT
You are about to leave this site.
Please be aware that your current cart is not saved yet and cannot be restored on the new site nor when you come back. If you want to save your cart please login in into your account.
myEppendorf
Centrifuge 5425/5425 R - Microcentrifuge
Product Information
Eppendorf microcentrifuges 5425 and 5425 R are true laboratory standards. These whisper quiet 24-place microcentrifuges offer an outstanding set of features for a broad range of molecular and cell biology applications in Eppendorf and PCR tubes from 0.2 to 5 mL. The refrigerated Centrifuge 5425 R provides precise temperature control for processing temperature-sensitive samples with its advanced cooling system.Centrifuge-5425
You will find additional download material at the bottom of this page
Products (9)
epServices (23)
Rotors (6)
Accessories (1)
VisioNize (2)
9 Products
|
|
|
|
Save Big! Save More! Gain great versatility with Centrifuge bundles. Promo valid till 20 Dec 2024. T&Cs apply.
|
Save Big! Save More! Gain great versatility with Centrifuge bundles. Promo valid till 20 Dec 2024. T&Cs apply.
|
|
|
|
Show more Products
Added to Your Cart
Product Information
Technical Data
Features
Product Information
These 24-place microcentrifuges have been engineered to be extremely quiet. Short runs up to 12 minutes are whisper quiet at an average noise level of 45 dB(A) and maximum speed of up to 21,300 × g. This is sufficient for centrifugation steps of most routinely used DNA/RNA purification kits. During longer runs the cooling fan works at full capacity to dissipate the heat for the remainder of the run. As successors to the popular Centrifuge 5424/5424 R, these two new models include everything you loved about the previous models, plus new rotors and software functions to make your everyday work more efficient and enjoyable.
The improved cooling system of the Centrifuge 5425 R ensures optimal separation results and reliable cooling at 4 °C, even at maximum rotor speed. With a short pre-cooling time of only 8 minutes (~21 °C to 4 °C), the centrifuge is ready for operation when you are.
The improved cooling system of the Centrifuge 5425 R ensures optimal separation results and reliable cooling at 4 °C, even at maximum rotor speed. With a short pre-cooling time of only 8 minutes (~21 °C to 4 °C), the centrifuge is ready for operation when you are.
Comprehensive range of 6 centrifuge rotors
The comprehensive range of 6 rotors broadens the spectrum of applications of this microcentrifuge. It includes, for the first time, a swing-bucket rotor that accommodates 96 PCR tubes for quick centrifugation of droplets and condensate before and after PCR/qPCR. When harvesting bacteria and yeast, a fixed-angle rotor for 10 x 5 mL tubes with screw or snap caps is ready for you.
Protect tube caps during centrifugation
The Eppendorf Kit rotor F-45-18-11-Kit enables centrifugation of samples in 18 x spin columns and 1.5 or 2.0 mL tubes at a maximum speed of 18,565 x g. This unique rotor offers a solution for the most common problem associated with working with MiniPrep spin column kits, open tube lids shearing off during elution steps. This problem traditionally occurs because standard rotors do not provide enough support for open tube lids during centrifugation. However, the Eppendorf Kit rotor is designed with an extended rim that serves as a rest for tube caps during centrifugation and protects them from shearing off. Your tube lids will no longer tear off during centrifugation!
Centrifuge rotor adapters for multiple applications
The Eppendor Rotor FA-10 x 5 makes harvesting of bacteria, yeast or cell culture in Eppendorf Tubes 5.0 mL and the purification of DNA or RNA and plasmid DNA easy. The adapters which are additionally available also allow the centrifugation of 1.5 or 2 mL tubes as well as HPLC and Cryo tubes without even changing the rotor.
Efficient lab and device management with VisioNize® Lab Suite
Are you interested in monitoring your lab devices and receiving notifications e.g., for device alarms? A digital, connected lab offers even more.
Gain access to a modular range of digital services and choose what works for your lab. VisioNize Lab Suite offers everything you need as a Lab Manager or Scientist to get started to digitally manage your lab for increased sample security, compliance needs and maintenance management.
Chart your own course to digital lab excellence! Find out more
Proud Owner of an Eppendorf product? Already registered?
Did you know that if you register your Eppendorf product with us you will get the following?
• 100 epPoints® (for each product you register) to redeem in our rewards shop
• Additional 3 months warranty when you register a Centrifuge, Shaker, CO2 Incubator or Cycler
• Entry in an exclusive Eppendorf prize draw (for each product you register)
• Get your personal product story to be posted on the Eppendorf website
Getting started is super easy! Either -
1. Download the Eppendorf App, scan and register OR
2. Visit our webpage, log onto your myEppendorf account and enter the product serial number
More information:www.eppendorf.com/productregistration
End-of-Life
Disposal of packaging
The packaging of the centrifuge contains different materials, this can include a wooden pallet, cardboard, a plastic dust cover, and some foam parts. Recycling of materials becomes more and more important every day: Are you aware that nearly all cardboard material is recycled in Europe? Our centrifuge packaging cardboard material consists of ca. 50% recycling material. Please support the global sustainability initiative of recycling valuable raw material by also collecting the freezer cardboard packaging material and disposing of it in the appropriate collection container at your organization. In respect to the plastic dust cover made of LD-PE and the foam parts, we recommend to select a dedicated recycling partner where PE material can be recycled. We suggest you contact your local waste hauler or facility management team to understand the available recycling options for your organization.
Disposal of instrument
Our centrifuges last for many years, but if they need to be replaced, we kindly ask you to fulfill local requirements for disposal of these instruments. We strongly recommend a certified local recycling partner with experience in instruments with active cooling. Keeping it “local“ reduces the impact of transportation, and the „certified“ aspect is recommended due to the safe and sustainable removal and recycling of the cooling liquids if it is a refrigerated centrifuge.
Decontamination
This piece of equipment was used in a laboratory and/ or was used to handle biological samples. Please keep in mind to adequately decontaminate the equipment which needs to be disposed. Check local requirements. For more information, get in contact with your local biosafety officer and/ or waste officer. Check if your local recycling partner has special instructions and/ or documentation requirements. You may also use the Eppendorf decontamination form sheet as guidance.
Read More
Read Less
Technical Data
Specifications | 5425 | 5425 R |
---|
Max. RCF | 21300 × g | 21300 × g |
Max. RCF with fixed-angle rotor | 21300 × g | 21300 × g |
Max. RCF with swing-bucket rotor | 3217 × g | 3217 × g |
Speed | 100 – 15,060 rpm | 100 – 15,060 rpm |
Product type | Centrifuges | Centrifuges |
Rotors available | 6 | 6 |
Max. capacity | 10 × 5.0 mL | 10 × 5.0 mL |
Acceleration time1) | 15 s | 15 s |
Deceleration time1) | 15 s | 15 s |
Timer | 10 s to 9:59 h, with continuous run function | 10 s to 9:59 h, with continuous run function |
SOFT brake function | 10 ramps | yes |
Noise level | average of 45 dB(A) in the first 12 minutes and < 51 dB(A) thereafter with Rotor FA-24x2 | < 54 dB(A) |
Power supply | 230 V, 50 – 60 Hz | 230 V, 50 – 60 Hz |
Max. power consumption | 280 W | 360 W |
Dimensions (W × D × H) | 24 × 39 × 24 cm / 9.5 × 15.4 × 9.5 in | 29 × 48 × 26 cm / 11.42 × 18.9 × 10.24 in |
Product weight | 15.6 kg / 34.4 lb | 21.0 kg / 46.3 lb |
Height (with open lid) | 48 cm / 18.8 in | 50.8 cm / 20.0 in |
Cooling | non-refrigerated | refrigerated |
Temperature range | − | -10 °C to +40 °C |
1)Acceleration and deceleration times may vary depending on rotor, load and voltage version.
Features
- Aerosol-tight Eppendorf QuickLock® lids for simple and safe handling
- Outstanding software features (e.g. adjustable acceleration and braking ramps, 3&nbs