- Compatible with BioNsight cloud software for remote process monitoring and remote analysis of all data sets
 - Compatible with Bioprocess Autosampler
 
DASGIP® Parallel Bioreactor System
Product Information
- for microbial applications, max. 250 sL/h gassing
 - 4-fold system with DASGIP® Bioblock
 
You will find additional download material at the bottom of this page
Technical Data
Features
Technical Data
| Specifications | DASGIP® System for Microbiology | 
|---|
| Application | Microbiology | 
| Number of parallel units | Up to 16 | 
| Software | DASware control, other DASware optional | 
| User Interface | Process computer with monitor | 
| Typical power consumption (4-fold system without process computer) | 
                                            
                                                
                                                    541 W (at 230 V)/ 467 W (at 115 V) (639 W/584 W without DASGIP Bioblock)  | 
                                    
                                
| Dimensions (W × D × H, 4-fold system without process computer) | 140 x 70 x 53 cm (55 x 28 x 21 in) | 
| Typical weight | 
                                            
                                                
                                                    96 kg  (78 kg without DASGIP Bioblock)  | 
                                    
                                
| Bacteria/Yeast/Fungi | yes | 
| Mammalian/Animal | yes | 
| Insect | yes | 
| Interchangeable Vessels | yes | 
| Validatable | no | 
| Stem cells | yes | 
| 
                                         Bioreactor type  | 
                                    |
| Vessels | Glass/single-use vessels | 
| Sterilization | 
                                            
                                                
                                                    Autoclavable/ pre-sterilized  | 
                                    
                                
| Total volume | 1.3 L to 2.1 L | 
| 
                                         Agitation  | 
                                    |
| Drive | Direct/magnetic overhead drive | 
| Speed ranges | 
                                            
                                                
                                                    100 – 1,600 rpm (standard)/ 30 – 1,250 rpm (optional)  | 
                                    
                                
| Impellers | Rushton-type | 
| 
                                         Gassing  | 
                                    |
| Gas supply | TMFC/Rotameter; sparger | 
| Standard gas flow rates | 0.5 – 250 sL/h, 0.5 – 150 sL/h CO2 (DASGIP MX4/4H, other modules available) | 
| Standard gas mixing | Air, N2, O2 and/or CO2 | 
| 
                                         Feeding  | 
                                    |
| Feed lines per vessel | Up to 8 | 
| Standard feed rates (depending on tube diameter) | 
                                            
                                                
                                                    0.3 – 9.5 mL/h to 13 – 420 mL/h (DASGIP MP8) 10 – 70 mL/h to 0.4 – 5 L/h (DASGIP MP4)  | 
                                    
                                
| 
                                         Monitoring and Control  | 
                                    |
| Temperature control | Heating and cooling integrated in DASGIP Bioblock (additional cooling fingers optional) | 
| Standard temperature range (at 25° C room temp.) | 5 K above cooling agent temperature – 99°C (DASGIP Bioblock)1) | 
| pH control | Acid and/or base, and other set-ups | 
| DO control | Cascade (agitation speed, optional O2 concentration, optional gas flow rate), and other set-ups | 
| ORP (redox) measurement | Optional | 
| Level/foam | Optional | 
| OD measurement | 
                                            
                                                
                                                    Optional (DASGIP OD4)  | 
                                    
                                
| Exhaust condensation | Water-cooled or liquid-free (Peltier with DASGIP EGC4) | 
| Exhaust analysis | 
                                            
                                                
                                                    Optional (DASGIP GA4)  | 
                                    
                                
| 
                                                    
                                                         1)Application-specific operating conditions apply.  | 
                                            |
Downloads: DASGIP® Parallel Bioreactor System
Content
Filter