MENU
CA | CAD
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
CA | CAD
-
- All Centrifuges
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifuge Consumables
- Centrifuge Tubes
- Centrifuge Plates
- Device Management Software
- Sample and Information Management
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Pipette Tips
- Bottle-Top Dispensers
- Pipette Controllers
- Dispenser & Pipette Accessories
- Automated Pipetting
- Automation Consumables
- Automation Accessories
- Liquid Handler & Pipette Services
Sorry, we couldn't find anything on our website containing your search term.
Sorry, we couldn't find anything on our website containing your search term.
Cell Culture FAQ: How to minimize the risk of a clogged microcapillary in cell injections?
Lab Academy
- Cell Biology
- Cell Culture
- Cell Culture Consumables
- FAQ
Answer by Dr. Sandra Stobrawa, Application Specialist Cell Handling at Eppendorf
This article appeared first in “Inside Cell Culture”, the monthly newsletter for cell culture professionals
Particles in the microinjection solution can quickly clog the fine opening (around 0.5 µm) of an injection capillary and prevents further microinjections with this capillary. Capillary exchange in general means slowing down of the injection experiment and increased time outside the incubator. However, the frequency of capillary exchange depends not only on the type and concentration of the microinjection sample, but also on the quality of the sample preparation.
For proper preparation of microinjections, all buffer solutions should be filtered through 0.2 µm pore size filters before adding the injection sample. And most importantly, the injection sample should be centrifuged for 15 - 20 min at 4 °C (approx. 16,000 x g) just before loading the supernatant into the microinjection capillary. This significantly reduces any precipitation in the sample and effectively prevents a clogged microcapillary.
Furthermore, your sample-loaded microcapillary should enter the medium of your injection dish with a continuous flow at low pressure generated by the microinjector (compensation pressure). This keeps the solution moving with the molecules, reducing the risk of clogging by debris from the medium surface. It also prevents the medium from entering the microcapillary by capillary forces, which would dilute the injection solution and impact your microinjection experiment.
Particles in the microinjection solution can quickly clog the fine opening (around 0.5 µm) of an injection capillary and prevents further microinjections with this capillary. Capillary exchange in general means slowing down of the injection experiment and increased time outside the incubator. However, the frequency of capillary exchange depends not only on the type and concentration of the microinjection sample, but also on the quality of the sample preparation.
For proper preparation of microinjections, all buffer solutions should be filtered through 0.2 µm pore size filters before adding the injection sample. And most importantly, the injection sample should be centrifuged for 15 - 20 min at 4 °C (approx. 16,000 x g) just before loading the supernatant into the microinjection capillary. This significantly reduces any precipitation in the sample and effectively prevents a clogged microcapillary.
Furthermore, your sample-loaded microcapillary should enter the medium of your injection dish with a continuous flow at low pressure generated by the microinjector (compensation pressure). This keeps the solution moving with the molecules, reducing the risk of clogging by debris from the medium surface. It also prevents the medium from entering the microcapillary by capillary forces, which would dilute the injection solution and impact your microinjection experiment.
Read more