text.skipToContent text.skipToNavigation

Accessories (5)


    • empty box for 8 Combitips® advanced (0.1 – 10 mL)
    • Eppendorf Quality, 1 piece
    • Sales stop – see www.eppendorf.com/easy-choice. Please order General Lab variant
    More Product Details ...
    Catalog no. 0030089952

      • contains one Combitips® advanced sample of each size and Adapter advanced 25 and 50 mL
      • Eppendorf Quality
      More Product Details ...
      Catalog no. 0030089936

        • 1-channel
        • 1 µL – 10 mL
        • incl. 1x Combitips® advanced 2.5 mL (green) tip and Pipette Holder 2
        • ACT-labeled: Independent third-party product sustainability validation by My Green Lab
        More Product Details ...
        Catalog no. 4982000012

        • 1-channel
        • 1 µL – 50 mL
        • incl. charging cable and Combitips® advanced assortment pack (1 tip of each size)
        • ACT-labeled: Independent third-party product sustainability validation by My Green Lab
        More Product Details ...
        Catalog no. 4987000029

        • 1-channel
        • 1 µL – 50 mL
        • incl. charging cable and Combitips® advanced assortment pack (1 tip of each size)
        • ACT-labeled: Independent third-party product sustainability validation by My Green Lab
        More Product Details ...
        Catalog no. 4987000010

        Technical Data

        Features

        Specifications Combitips® advanced - 0030089464
        ACT label yes 
        Product type Consumables 
        Pipetting type Positive displacement system 
        Tip size 10 mL 
        Color code orange 
        Tip color colorless tips 
        Purity grade Eppendorf Quality 
        Packaging 100 pcs. (4 bags × 25 pcs.) 
        Open system (third party consumables) no 

        Performance data with Multipette E3 & E3x / Repeater E3 & E3x

        Random measurement error 100 µL: ± 3.5%; ± 3.5 µL
        1000 µL: ± 0.25%; ± 2.5 µL
        5000 µL: ± 0.25%; ± 12.5 µL
        10000 µL: ± 0.15%; ± 15 µL 
        Systematic measurement error 100 µL: ± 1.5%; ± 1.5 µL
        1000 µL: ± 0.5%; ± 5 µL
        5000 µL: ± 0.4%; ± 20 µL
        10000 µL: ± 0.4%; ± 40 µL 
        Volume range 100 – 10,000 µL  

        Performance data with Multipette M4 / Repeater M4

        Random measurement error 100 µL: ± 4%; ± 4 µL
        200 µL: ± 0.6%; ± 1.2 µL
        1000 µL: ± 0.4%; ± 4 µL
        2000 µL: ± 0.25%; ± 5 µL 
        Systematic measurement error 100 µL: ± 3%; ± 3 µL
        200 µL: ± 0.5%; ± 1 µL
        1000 µL: ± 0.5%; ± 5 µL
        2000 µL: ± 0.5%; ± 10 µL 
        Volume range 100 – 2,000 µL