Dispensing head 96-channel 5 – 1,000 µL

Catalog No. 5069000535

Product Information

  • 96-channel, for epMotion® 96 Flex in hard shell case, needs base device for operation
  • 5 – 1,000 µL

You will find additional download material at the bottom of this page

Pipette Tips (6)


    • without filter
    • Eppendorf Quality, 5 – 300 µL, ACT, 2,304 tips (24 trays × 96 tips)
    More Product Details ...
    Catalog no. 0030014464

    • with filter
    • PCR clean, 10 – 1,000 µL, ACT, 2,304 tips (24 trays × 96 tips)
    More Product Details ...
    Catalog no. 0030014510

      • with filter
      • PCR clean and sterile, 10 – 1,000 µL, ACT, 2,304 tips (24 trays × 96 tips)
      More Product Details ...
      Catalog no. 0030014570

      • with filter
      • PCR clean, 5 – 300 µL, ACT, 2,304 tips (24 trays × 96 tips)
      More Product Details ...
      Catalog no. 0030014472

        • without filter
        • Eppendorf Quality, 10 – 1,000 µL, ACT, 2,304 tips (24 trays × 96 tips)
        More Product Details ...
        Catalog no. 0030014502

          • with filter
          • PCR clean and sterile, 5 – 300 µL, ACT, 2,304 tips (24 trays × 96 tips)
          More Product Details ...
          Catalog no. 0030014537

          Technical Data

          Features

          Specifications Dispensing head 5-1000µL - 5069000535
          Pipetting type Air-cushion system 
          Number of channels 96-channel 
          Application Cell culture, Molecular biology 
          Volume range 5 – 1,000 µL 
          Operating mode
          Autoclavable no 
          Power supply
          Consumables epT.I.P.S.® Motion Reload System 
          Max. power consumption
          Dimensions (W × D × H)
          Product weight 2.7 kg / 6.0 lb
           
          Testing volume 300 µL Tips
          5 µL
          30 µL
          150 µL
          300 µL
          1000 µL Tips
          10 µL
          100 µL
          500 µL
          1000 µL 
          Systematic measurement error (determined in pipette mode) 300 µL Tips
          ≤ 3 % (not guaranteed, individual adjustment of device and dispensing head may be required)
          ≤ 2.5 %
          ≤ 1.5 %
          ≤ 1.5 %
          1000 µL Tips
          ≤ 3 % (not guaranteed, individual adjustment of device and dispensing head may be required)
          ≤ 1.5 %
          ≤ 1.5 %
          ≤ 1 % 
          Random measurement error (determined in pipette mode) 300 µL Tips
          ≤ 2.5 % at 30 µL
          1000 µL Tips
          ≤ 1.5 % at 100 µL 
          SLAS/ANSI positions