text.skipToContent text.skipToNavigation
No results found
Search Suggestions

Accessories (6)


    • for 8 Combitips® advanced (0.1 – 10 mL)
    • Eppendorf Quality, 1 piece
    More Product Details ...
    Catalog no. 0030089758

      • empty box for 8 Combitips® advanced (0.1 – 10 mL)
      • Eppendorf Quality, 1 piece
      • Replaces order no. 0030089758
      More Product Details ...
      Catalog no. 0030089952

        • contains one Combitips® advanced sample of each size and Adapter advanced 25 and 50 mL
        • Eppendorf Quality
        More Product Details ...
        Catalog no. 0030089936

          • 1-channel
          • 1 µL – 10 mL
          • incl. 1x Combitips® advanced 2.5 mL (green) tip and Pipette Holder 2
          More Product Details ...
          Catalog no. 4982000012

            • 1-channel
            • 1 µL – 50 mL
            • incl. charging cable and Combitips® advanced assortment pack (1 tip of each size)
            More Product Details ...
            Catalog no. 4987000029

              • 1-channel
              • 1 µL – 50 mL
              • incl. charging cable and Combitips® advanced assortment pack (1 tip of each size)
              More Product Details ...
              Catalog no. 4987000010

              Technical Data

              Features

              Specifications Combitips® advanced - 0030089650
              ACT label yes 
              Product type Consumables 
              Pipetting type Positive displacement system 
              Tip size 2.5 mL 
              Color code green 
              Tip color colorless tips 
              Purity grade Biopur® 
              Packaging 100 pcs., individually blister-wrapped 
              Open system (third party consumables) no 

              Performance data with Multipette E3 & E3x / Repeater E3 & E3x

              Random measurement error 25 µL: ± 3.5%; ± 0.875 µL
              250 µL: ± 0.45%; ± 1.125 µL
              1250 µL: ± 0.3%; ± 3.75 µL
              2500 µL: ± 0.15%; ± 3.75 µL 
              Systematic measurement error 25 µL: ± 2%; ± 0.5 µL
              250 µL: ± 0.8%; ± 2 µL
              1250 µL: ± 0.5%; ± 6.25 µL
              2500 µL: ± 0.5%; ± 12.5 µL 
              Volume range 25 – 2,500 µL  

              Performance data with Multipette M4 / Repeater M4

              Random measurement error 25 µL: ± 8%; ± 2 µL
              50 µL: ± 0.8%; ± 0.4 µL
              250 µL: ± 0.6%; ± 1.5 µL
              500 µL: ± 0.3%; ± 1.5 µL 
              Systematic measurement error 25 µL: ± 4%; ± 1 µL
              50 µL: ± 0.8%; ± 0.4 µL
              250 µL: ± 0.6%; ± 1.5 µL
              500 µL: ± 0.5%; ± 2.5 µL 
              Volume range 25 – 500 µL