You are about to leave this site.
Please be aware that your current cart is not saved yet and cannot be restored on the new site nor when you come back. If you want to save your cart please login in into your account.
Eppendorf Research® plus
Research plus 24-channel, 5 – 100 µL, light yellow, 4.5 mm cone distance, incl. epT.I.P.S. Box 2.0 with 96 pipette tips
![Research plus 24-channel, 5 – 100 µL, light yellow, 4.5 mm cone distance, incl. epT.I.P.S. Box 2.0 with 96 pipette tips](/product-media/img/global/10961540/Eppendorf_Liquid-Handling_Research-plus_24-channel-5-100-uL-light-yellow-45mm-cone-distance-incl-epTIPS-Box-20-96-pipette-tips_product.jpg?imwidth=920)
Eppendorf Research® plus manual pipettes feature a temporary adjustment option for challenging liquid classes
![Eppendorf Research® plus manual pipettes feature a temporary adjustment option for challenging liquid classes Eppendorf Research® plus manual pipettes feature a temporary adjustment option for challenging liquid classes](/product-media/img/global/6583/Eppendorf_Liquid-Handling_Research-plus_detail-1_product.jpg?imwidth=920)
Eppendorf Research® plus manual pipette 4-digit display for easy and precise volume adjustment
![Eppendorf Research® plus manual pipette 4-digit display for easy and precise volume adjustment Eppendorf Research® plus manual pipette 4-digit display for easy and precise volume adjustment](/product-media/img/global/149704/Eppendorf_Liquid-Handling_Research-plus_product.jpg?imwidth=920)
Eppendorf Research® plus 16 and 24-channel mechanical pipettes and 384-well plate
![Eppendorf Research® plus 16 and 24-channel mechanical pipettes and 384-well plate Eppendorf Research® plus 16 and 24-channel mechanical pipettes and 384-well plate](/product-media/img/global/542946/Eppendorf_Liquid-Handling_Research-plus-16-channel-pipette-24-channel-pipette-100uL_Research-plus-16-channel-pipette-24-channel-pipette-100uL_product.jpg?imwidth=920)
Fill 384-well plates with ease using Eppendorf multi-channel pipettes with 16 or 24 channels
![Fill 384-well plates with ease using Eppendorf multi-channel pipettes with 16 or 24 channels Fill 384-well plates with ease using Eppendorf multi-channel pipettes with 16 or 24 channels](/product-media/img/global/540227/Eppendorf_Liquid-Handling_Research-plus-24-channel-pipette-epTIPS-Dualfilter_Research-plus-24-channel-pipette-epTIPS-Dualfilter-close-up-1_product.jpg?imwidth=920)
Eppendorf multi-channel pipettes with 16 or 24 tip cones are ideal to dispense multiple samples in 384-well plates
![Eppendorf multi-channel pipettes with 16 or 24 tip cones are ideal to dispense multiple samples in 384-well plates Eppendorf multi-channel pipettes with 16 or 24 tip cones are ideal to dispense multiple samples in 384-well plates](/product-media/img/global/540217/Eppendorf_Liquid-Handling_Research-plus-24-channel-pipette-epTIPS-384_Research-plus-24-channel-pipette-filling-384-well-plate_product.jpg?imwidth=920)
Male laboratory technician works at the bench with PCR, Eppendorf ThermoMixer® and dispenses liquid in a plate
![Male laboratory technician works at the bench with PCR, Eppendorf ThermoMixer® and dispenses liquid in a plate Male laboratory technician works at the bench with PCR, Eppendorf ThermoMixer® and dispenses liquid in a plate](/product-media/img/global/540051/Eppendorf_Liquid-Handling_16-channel-pipette-1_Pipetting-384-well-plate_lab-scene.jpg?imwidth=920)
The Eppendorf Research® plus 24-channel pipette pipetting into agarose gel
![The Eppendorf Research® plus 24-channel pipette pipetting into agarose gel Eppendorf multi-channel pipette with 24 tips dispensing liquid into agarose gel for gel electrophoresis](/product-media/img/global/540104/Eppendorf_Liquid-Handling_24-channel-pipette-Pipetting-into-agarose-gel_lab-scene.jpg?imwidth=920)
Two Female Scientists Working with Eppendorf Research® plus 16-channel Pipette and Eppendorf twin.tec® PCR Plates
![Two Female Scientists Working with Eppendorf Research® plus 16-channel Pipette and Eppendorf twin.tec® PCR Plates Two Female Scientists Working with Eppendorf Research® plus 16-channel Pipette and Eppendorf twin.tec® PCR Plates](/product-media/img/global/1712842/Eppendorf_Liquid-Handling_Research-plus_lab-scene.jpg?imwidth=920)
How to Pipette in 5 Simple Steps
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/Wx8clzD-CO4/hqdefault.jpg)
384. Ready. Set. Pipette!
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/OvKWA6SvGVc/hqdefault.jpg)
Userguide : Deactivating the spring-loaded tip cone
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/hk9zQAuVt9k/hqdefault.jpg)
How to Fill Microplates Faster
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/RmXqbyWYr20/hqdefault.jpg)
Userguide : Replacement of the O-rings
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/eq7pWXPERHw/hqdefault.jpg)
Userguide : Disassembly
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/zIo4019JuPE/hqdefault.jpg)
Userguide : Assembly
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/KOnUJaXpwuo/hqdefault.jpg)
Userguide : Reverse Pipetting
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/VtJOOCspyZI/hqdefault.jpg)
How to Take Care of Your Pipette
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/0Kh15yT8FJw/hqdefault.jpg)
Userguide : Forward pipetting
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/ENljhQUqDc4/hqdefault.jpg)
384 Wells? No problem.
Videos not loading, because cookies have been rejected. Change your
![](https://img.youtube.com/vi/SjpnlLCk0nw/hqdefault.jpg)
Product Information
- 24-channel, 4.5 mm cone distance
- 5 – 100 µL, light yellow, variable volume
- incl. epT.I.P.S.® Box 2.0 with 384 pipette tips
You will find additional download material at the bottom of this page
Pipette Tips (4)
Services (8)
Accessories (5)
4 Pipette Tips
Catalog no.
0030078861
|
Catalog no.
0030076010
|
Catalog no.
0030076281
|
Catalog no.
0030076052
|
Show more Products
Technical Data
Features
Specifications | Eppendorf Research® plus - 3125000109 |
---|
ACT label | − |
Product type | Pipettes |
Pipetting type | Air-cushion system |
Number of channels | 24-channel |
Volume range | 5 – 100 µL |
Color code | light yellow |
Volume increment | 0.1 µL |
Operating mode | mechanical |
Spring-loaded tip cone | yes |
Random measurement error |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
Systematic measurement error |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
Autoclavable | yes |
Consumables | only epT.I.P.S. 384 |
Open system (third party consumables) | yes |
Delivery content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes |
- Mechanical air-cushion pipette with standard 3-button operation (one operating element for volume selection, one for pipetting, and one for tip ejection)
- Ideal for accurate, easy, and ergonomic manual pipetting of aqueous solutions
- Feel the difference in weight and pipetting forces: Designed according to the Eppendorf PhysioCare Concept® principles
- Benefit from one of the lowest operating and tip ejection forces on the pipette market, helping to reduce hand and arm strain
- Enjoy minimal tip attachment forces due to a spring-loaded tip cone (available for all pipettes up to 1 mL)
- Temporarily adjust your pipette in seconds for better accuracy when pipetting challenging liquids like ethanol or when pipetting at high altitudes. Return to factory adjustment without calibration
- Autoclave the entire pipette or only the lower part according to your needs and applications to ensure a proper decontamination
- Premium material ensures a high UV and chemical resistance
- With the channel display, you can always use the pipette in the same position
- Increase your flexibility and remove individual channels as necessary