- Compatible with BioNsight cloud software for remote process monitoring and remote analysis of all data sets
- Compatible with Bioprocess Autosampler
DASGIP® Parallel Bioreactor System
Product Information
- for cell culture, max. 50 sL/h gassing
- 4-fold system with DASGIP® Bioblock
You will find additional download material at the bottom of this page
Technical Data
Features
Technical Data
| Specifications | DASGIP® Parallel Bioreactor System | 
|---|
| Application | Cell culture | 
| Number of parallel units | Up to 16 | 
| Software | DASware control, other DASware optional | 
| User Interface | Process computer with monitor | 
| Typical power consumption (4-fold system without process computer) | 480 W (at 230 V)/ 432 W (at 115 V) (595 W/552 W without DASGIP Bioblock) | 
| Dimensions (W × D × H, 4-fold system without process computer) | − | 
| Typical weight | 78 kg (60 kg without DASGIP Bioblock) | 
| Bacteria/Yeast/Fungi | yes | 
| Mammalian/Animal | yes | 
| Insect | yes | 
| Interchangeable Vessels | yes | 
| Validatable | no | 
| Stem cells | yes | 
| Bioreactor type | |
| Vessels | Glass/single-use vessels | 
| Sterilization | Autoclavable/ pre-sterilized | 
| Total volume | 1.5 L to 2.3 L | 
| Agitation | |
| Drive | Direct/magnetic overhead drive | 
| Speed ranges | 30 – 1,250 rpm (standard)/ 100 – 1,600 rpm (optional) | 
| Impellers | Pitched-blade | 
| Gassing | |
| Gas supply | TMFC; overlay and/or sparger | 
| Standard gas flow rates | 0.1 – 50 sL/h, 0.1 – 40 sL/h CO2 (DASGIP MX4/4, other modules available) | 
| Standard gas mixing | Air, N2, O2 and/or CO2 | 
| Feeding | |
| Feed lines per vessel | Up to 8 | 
| Standard feed rates (depending on tube diameter) | 0.3 – 9.5 mL/h to 13 – 420 mL/h (DASGIP MP8) 10 – 70 mL/h to 0.4 – 5 L/h (DASGIP MP4) | 
| Monitoring and Control | |
| Temperature control | Heating and cooling integrated in DASGIP Bioblock (additional cooling fingers optional) | 
| Standard temperature range (at 25° C room temp.) | 5 K above cooling agent temperature – 99°C (DASGIP Bioblock)1) | 
| pH control | − | 
| DO control | Cascade (O2 concentration, gas flow rate), and other set-ups | 
| ORP (redox) measurement | - | 
| Level/foam | Optional | 
| OD measurement | Optional (DASGIP OD4) | 
| Exhaust condensation | Water-cooled or liquid-free (Peltier with DASGIP EGC4) | 
| Exhaust analysis | Optional (DASGIP GA4) | 
| 1)Application-specific operating conditions apply. | |
Downloads: DASGIP® Parallel Bioreactor System
Content