Eppendorf Research® plus - Mechanical Pipette
The Eppendorf Research® plus mechanical pipettes are available as 1-, 8-, 12-, 16-, 24-channel and adjustable tip spacing variant Move It®
The Eppendorf Research® plus was the first mechanical pipette to receive the "My Green Lab" ACT label
Eppendorf Research® plus manual pipettes feature a temporary adjustment option for challenging liquid classes
Eppendorf Research® plus multi-channel pipettes with 8 or 12 tip cones for PCR-strips and 96-well plates
Eppendorf multi-channel pipettes with 16 or 24 tip cones are ideal to dispense multiple samples in 384-well plates
Male laboratory technician works at the bench with PCR, Eppendorf ThermoMixer® and dispenses liquid in a plate
How to Pipette in 5 Simple Steps
Videos not loading, because cookies have been rejected. Change your
How to Fill Microplates Faster
Videos not loading, because cookies have been rejected. Change your
Multi-Channel Pipette Tip Attachment
Videos not loading, because cookies have been rejected. Change your
384. Ready. Set. Pipette!
Videos not loading, because cookies have been rejected. Change your
384 Wells? No problem.
Videos not loading, because cookies have been rejected. Change your
Userguide : Forward pipetting
Videos not loading, because cookies have been rejected. Change your
Userguide : Reverse Pipetting
Videos not loading, because cookies have been rejected. Change your
How to Take Care of Your Pipette
Videos not loading, because cookies have been rejected. Change your
Userguide : Disassembly
Videos not loading, because cookies have been rejected. Change your
Userguide : Assembly
Videos not loading, because cookies have been rejected. Change your
Userguide : Deactivating the spring-loaded tip cone
Videos not loading, because cookies have been rejected. Change your
Userguide : Replacement of the O-rings
Videos not loading, because cookies have been rejected. Change your
Userguide : Pipette calibration
Videos not loading, because cookies have been rejected. Change your
-
New
Product Information
The Eppendorf Research plus is one of the safest and most ergonomic mechanical pipettes available. Meeting the highest needs of precision and accuracy while providing high flexibility via a large number of variants, the Research plus will become an indispensable companion in your lab. This micropipette is remarkably light, both in terms of weight and pipetting forces, which helps you to avoid hand and arm strain. The 16- and 24-channel pipette system combines proven concepts with new innovations and facilitates quick & easy manual pipetting in 384-well plates.Eppendorf Research® plus Pipette
You will find additional download material at the bottom of this page
Products (35)
Sets & Bundles (5)
Services (43)
Accessories (19)
Spare Parts (47)
35 Products
RM 1,363.00
|
RM 1,363.00
|
RM 4,570.00
|
RM 5,000.00
|
RM 5,327.00
|
RM 5,658.00
|
RM 1,363.00
|
RM 1,363.00
|
RM 5,327.00
|
RM 5,658.00
|
Show more Products
Product Information
Technical Data
Applications
Features
The light pipette for effortless pipetting
The Eppendorf Research plus mechanical pipette is the result of over 60 years of experience in liquid handling and is one of the most commonly used pipettes in the world. Thanks to the pioneering Eppendorf PhysioCare Concept®, the Research plus is highly ergonomic and protects your health in the laboratory. It features very low weight and operation forces, is extremely reliable, fully autoclavable and easy to use.
With a variety of options available, including single-channel pipettes with fixed or variable volume, multi-channel pipette options with 8, 12, 16 or 24 channels, and our Research plus Move It adjustable tip spacing micropipettes, we are confident that we can offer the right choice for your application.
It is a good feeling to know you are doing the right thing – to know you are working with one of the most renowned and advanced pipettes in the world. A spring-loaded tip cone, a temporary adjustment option, an improved volume display – and all that in a light, fully autoclavable pipette: That is the Eppendorf Research plus manual pipette. In 2021, the Research plus single-channel pipette line-up with variable volume has been certified with an ACT® Environmental Impact Factor Label by the My Green Lab® non-profit organization, making it the ideal choice for labs looking for more sustainable products.
Accoladed with a SelectScience Seal of Quality
The Research plus mechanical lab pipette was accoladed with a “Seal of Quality” by SelectScience®. These seals are given to the top 0.1 % of products used in laboratories that have received more than 100 positive reviews on the esteemed SelectScience platform. The award is praised as providing invaluable insights for scientists and intends to help them choose the ideal lab product for their working environment.
Which level of flexibility and safety do you require?
Variable volume pipettes for highest flexibility
• Adjust dispensing volume within a range of 0.1 µL and 10 mL
• Selected volume is displayed in the large 4-digit volume display
• Quick and accurate volume settings
• Available as single-, 8-, 12-, 16- and 24-channel as well as Move It adjustable tip spacing pipettes
Fixed-volume pipettes for a fast and reliable workflow
• Work at a faster pace with fixed set volumes
• Reduce the chance of errors compared to a pipette with variable volume
• Fast and easy calibration
• Available as single-channel pipettes in 12 different variants
• Perfect for beginners and labs on a budge
Choose the correct pipette set for your application needs
Not all experiments are based on the same working conditions. Depending on the vessel type, you can choose from single-channel microliter pipettes that are ideal for tubes, and multi-channel pipettes better suited for plates.
• Tubes: Single-channel pipettes with fixed or variable volume
• 96- and 24-well plates: 8- and 12-channel pipettes
• 384-well plates: 16- and 24-channel pipettes
• Vessel type changes: Move It adjustable tip spacing pipettes
Fatigue-free and ergonomic pipetting
The Eppendorf Research plus microliter pipette is intuitive to operate, provides a perfect balance and minimizes operator strain and fatigue, developed in line with the Eppendorf PhysioCare Concept. The result is a light and well-balanced pipette, equipped with the unique spring-loaded tip cone and SoftEject features. Operating forces can be reduced even further by combining the Research plus 16- and 24- channel pipettes with the epT.I.P.S. 384 pipette tips with SoftAttach technology.
Spring-loaded tip cones for reliable tip fit and effortless attachment
Eppendorf pipettes with spring-loaded tip cone save you time and energy. With haptic feedback, all it takes is one gentle push-down for easy tip attachment. The spring limits the attachment forces and at the same time guarantees a reproducible and safe tip fit. This clever design provides increased user-to-user reproducibility and more consistent results between different lab members. All micropipettes from Eppendorf up to 1,000 µL (except Move It 300 µL models) are equipped with the spring-loaded tip cone feature.
SoftEject technology reduces tip ejection forces by 50 %
All non-adjustable multi-channel pipettes from Eppendorf use the innovative SoftEject technology to ensure that during each single tip ejection stroke, the outside tips eject before the inside tips. This is not noticeable to the user but reduces tip ejection forces by 50 %. You just lightly press the ejection button once and the tips are automatically ejected in succession.
Speed up your workflows with mechanical multi-channel pipettes
Do you need to easily and quickly fill a 24-, 96- or even 384-well microplate? With the lightweight Eppendorf Research plus 8-, 12-, 16- and 24-channel pipettes you can perform high volume precision work faster. The spring-loaded tip cones help you to load multi-channel tips quickly and securely without a need for rocking. Get extremely consistent sample pickup across all channels and maximize user-to-user reproducibility for more consistent results among members of the lab.
96-well plates
Easily fill 96-well plates with Research plus 8- or 12-channel pipettes featuring a cone distance of 9 mm. Our 1,200 µL volume pipettes are ideal for filling deepwell plates.
👉 Choose epT.I.P.S. pipette tips for 9 mm spacing
Choose the Research plus 16- or 24-channel pipettes or selected Move It adjustable tip spacing pipette models featuring cone distances of (min.) 4.5 mm for applications in 384-well plates. Fill a complete row or column to start 16 or 24 reactions simultaneously in just one step.
👉 Choose epT.I.P.S. 384 pipette tips for 4.5 mm spacing
Fast and efficient pipetting into 384-well plates
Do you need an efficient manual pipetting method for 384-well plate applications? The 16- and 24- channel pipettes from Eppendorf make working with 384-well plates convenient, ergonomic and safe.
Your benefits:
• Tedious alternate well pipetting with 8- or 12-channel pipettes is a thing of the past
• Processing one 384-well plate instead of four 96-well plates improves pipetting efficiency since the number of pipetting steps is reduced by 50 %
• Start 16 or 24 reactions simultaneously for equal starting conditions
• Avoid accidental well misidentification and repeating of experiments
• epT.I.P.S. 384 pipette tips are designed in perfect harmony with these microliter pipettes
epT.I.P.S. 384 with SoftAttach technology for 16- and 24-channel pipettes
For the first time, pipette tips are equipped with elastic forming groves. They allow the tips to stretch as much as the shape of the tip cone predefines. Meanwhile, the tip attachment and ejection forces are greatly reduced. With this latest expression of the Eppendorf PhysioCare Concept, this system enables a perfect tip seal while operating forces are reduced to a minimum.
Your benefits:
• Reliable tip fit and tightness
• Smooth and even tip attachment
• Tip attachment forces reduced by 40 % per cone compared to 8- and 12-channel pipettes
• Reduced ejection forces
• Perfect tip alignment due to extraordinary coaxiality for safe plate maneuvering and liquid transfer
• Extremely fine tip shape to perfectly hit all 384 wells
Disposal of packaging and the pipette at the end of its lifecycle
The packaging of Eppendorf pipettes & dispensers contains different materials, this includes cardboard, plastic foil, as well as pipette tip boxes. Our pipette packaging cardboard material consists of approx. 77 % recycling material. Please support the global sustainability initiative of recycling valuable raw material by collecting the cardboard and disposing of it in the appropriate collection container at your organization. In respect to the wrapping foils made of LD-PE, we recommend to select a dedicated recycling partner where PE material can be recycled.
Eppendorf liquid handling instruments are designed for many years of use – should the need arise to dispose of an instrument however, please note that it may potentially be contaminated. Therefore, recycling of pipettes or dispensers may be challenging. Please contact your local biosafety officer and/or your local waste management. In many countries, this waste must be burned due to legal restrictions. We recommend you to work with a certified local recycling partner with experience in lab waste however to examine your options.
Read More
Read Less
Specifications | Eppendorf Research® plus - 3123000012 | Eppendorf Research® plus - 3123000020 | Eppendorf Research® plus - 3125000010 | Eppendorf Research® plus - 3125000028 | Eppendorf Research® plus - 3125000079 | Eppendorf Research® plus - 3125000087 | Eppendorf Research® plus - 3123000098 | Eppendorf Research® plus - 3123000039 | Eppendorf Research® plus - 3125000095 | Eppendorf Research® plus - 3125000109 | Eppendorf Research® plus - 3123000047 | Eppendorf Research® plus - 3125000036 | Eppendorf Research® plus - 3125000044 | Eppendorf Research® plus - 3123000055 | Eppendorf Research® plus - 3123000101 | Eppendorf Research® plus - 3125000052 | Eppendorf Research® plus - 3125000060 | Eppendorf Research® plus - 3123000063 | Eppendorf Research® plus - 3125000214 | Eppendorf Research® plus - 3125000222 | Eppendorf Research® plus - 3123000144 | Eppendorf Research® plus - 3123000071 | Eppendorf Research® plus - 3123000080 | Eppendorf Research® plus - 3124000016 | Eppendorf Research® plus - 3124000024 | Eppendorf Research® plus - 3124000032 | Eppendorf Research® plus - 3124000040 | Eppendorf Research® plus - 3124000059 | Eppendorf Research® plus - 3124000067 | Eppendorf Research® plus - 3124000075 | Eppendorf Research® plus - 3124000083 | Eppendorf Research® plus - 3124000091 | Eppendorf Research® plus - 3124000105 | Eppendorf Research® plus - 3124000113 | Eppendorf Research® plus - 3124000121 |
---|
ACT label | yes | yes | − | − | − | − | yes | yes | − | − | yes | − | − | yes | yes | − | − | yes | − | − | yes | yes | yes | − | − | − | − | − | − | − | − | − | − | − | − |
Product type | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes |
Pipetting type | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system |
Number of channels | 1-channel | 1-channel | 8-channel | 12-channel | 16-channel | 24-channel | 1-channel | 1-channel | 16-channel | 24-channel | 1-channel | 8-channel | 12-channel | 1-channel | 1-channel | 8-channel | 12-channel | 1-channel | 8-channel | 12-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel |
Volume range | 0.1 – 2.5 µL | 0.5 – 10 µL | 0.5 – 10 µL | 0.5 – 10 µL | 1 – 20 µL | 1 – 20 µL | 2 – 20 µL | 2 – 20 µL | 5 – 100 µL | 5 – 100 µL | 10 – 100 µL | 10 – 100 µL | 10 – 100 µL | 20 – 200 µL | 30 – 300 µL | 30 – 300 µL | 30 – 300 µL | 100 – 1,000 µL | 120 – 1,200 µL | 120 – 1,200 µL | 0.25 – 2.5 mL | 0.5 – 5 mL | 1 – 10 mL | 10 µL | 10 µL | 20 µL | 20 µL | 25 µL | 50 µL | 100 µL | 200 µL | 200 µL | 250 µL | 500 µL | 1,000 µL |
Color code | dark gray | medium gray | medium gray | medium gray | light pink | light pink | light gray | yellow | light yellow | light yellow | yellow | yellow | yellow | yellow | orange | orange | orange | blue | dark green | dark green | red | violet | turquoise | medium gray | yellow | light gray | yellow | yellow | yellow | yellow | yellow | blue | blue | blue | blue |
Volume increment | 0.002 µL | 0.01 µL | 0.01 µL | 0.01 µL | 0.02 µL | 0.02 µL | 0.02 µL | 0.02 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.2 µL | 0.2 µL | 0.1 µL | 0.1 µL | 1 µL | 1 µL | 1 µL | 0.002 mL | 0.005 mL | 0.01 mL | − | − | − | − | − | − | − | − | − | − | − | − |
Operating mode | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical | mechanical |
Spring-loaded tip cone | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | no | no | no | no | no | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Random measurement error |
0.10 µL: ± 12%; ± 0.012 µL 0.25 µL: ± 6%; ± 0.015 µL 1.25 µL: ± 1.5%; ± 0.01875 µL 2.5 µL: ± 0.7%; ± 0.0175 µL |
0.5 µL: ± 5%; ± 0.025 µL 1 µL: ± 1.8%; ± 0.018 µL 5 µL: ± 0.8%; ± 0.04 µL 10 µL: ± 0.4%; ± 0.04 µL |
0.5 µL: ± 8%; ± 0.04 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 2%; ± 0.1 µL 10 µL: ± 1%; ± 0.1 µL |
0.5 µL: ± 8%; ± 0.04 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 2%; ± 0.1 µL 10 µL: ± 1%; ± 0.1 µL |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 3%; ± 0.03 µL 2 µL: ± 1.5%; ± 0.03 µL 10 µL: ± 0.6%; ± 0.06 µL 20 µL: ± 0.3%; ± 0.06 µL |
1 µL: ± 3%; ± 0.03 µL 2 µL: ± 1.5%; ± 0.3 µL 10 µL: ± 0.6%; ± 0.06 µL 20 µL: ± 0.3%; ± 0.06 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
5 µL: ± 2%; ± 0.1 µL 10 µL: ± 1%; ± 0.1 µL 50 µL: ± 0.3%; ± 0.15 µL 100 µL: ± 0.2%; ± 0.2 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.3%; ± 0.3 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.3%; ± 0.3 µL |
10 µL: ± 1.4%; ± 0.14 µL 20 µL: ± 0.7%; ± 0.14 µL 100 µL: ± 0.3%; ± 0.3 µL 200 µL: ± 0.2%; ± 0.4 µL |
15 µL: ± 1.4%; ± 0.21 µL 30 µL: ± 0.7%; ± 0.21 µL 150 µL: ± 0.3%; ± 0.45 µL 300 µL: ± 0.2%; ± 0.6 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.3%; ± 0.9 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.3%; ± 0.9 µL |
50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 0.6%; ± 0.6 µL 500 µL: ± 0.2%; ± 1 µL 1000 µL: ± 0.2%; ± 2 µL |
50 µL: ± 1.2%; ± 0.6 µL 120.0 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
50 µL: ± 1.2%; ± 0.6 µL 120.0 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 3.6%; ± 3.6 µL |
125 µL: ± 1.4%; ± 1.75 µL 250 µL: ± 1.2%; ± 3 µL 1250 µL: ± 0.2%; ± 2.5 µL 2500 µL: ± 0.2%; ± 5 µL |
250 µL: ± 1.2%; ± 3 µL 500 µL: ± 0.6%; ± 3 µL 2500 µL: ± 0.25%; ± 6.25 µL 5000 µL: ± 0.15%; ± 7.5 µL |
500 µL: ± 1.2%; ± 6 µL 1000 µL: ± 0.6%; ± 6 µL 5000 µL: ± 0.2%; ± 10 µL 10000 µL: ± 0.15%; ± 15 µL |
10 µL: ± 0.6%; ± 0.06 µL | 10 µL: ± 0.6%; ± 0.06 µL | 20 µL: ± 0.3%; ± 0.06 µL | 20 µL: ± 0.3%; ± 0.06 µL | 25 µL: ± 0.3%; ± 0.075 µL | 50 µL: ± 0.3%; ± 0.15 µL | 100 µL: ± 0.2%; ± 0.2 µL | 200 µL: ± 0.2%; ± 0.4 µL | 200 µL: ± 0.2%; ± 0.4 µL | 250 µL: ± 0.2%; ± 0.5 µL | 500 µL: ± 0.2%; ± 1 µL | 1000 µL: ± 0.2%; ± 2 µL |
Systematic measurement error |
0.10 µL: ± 48%; ± 0.048 µL 0.25 µL: ± 12%; ± 0.03 µL 1.25 µL: ± 2.5%; ± 0.031 µL 2.5 µL: ± 1.4%; ± 0.035 µL |
0.5 µL: ± 8%; ± 0.04 µL 1 µL: ± 2.5%; ± 0.025 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 1%; ± 0.1 µL |
0.5 µL: ± 12%; ± 0.06 µL 1 µL: ± 8%; ± 0.08 µL 5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL |
0.5 µL: ± 12%; ± 0.06 µL 1 µL: ± 8%; ± 0.08 µL 5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL |
1 µL: ± 12%; ± 0.12 µL 2 µL: ± 8%; ± 0.16 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
1 µL: ± 12%; ± 0.12 µL 2 µL: ± 8%; ± 0.16 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
1 µL: ± 10%; ± 0.1 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 1.2%; ± 0.12 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 10%; ± 0.1 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 1.2%; ± 0.12 µL 20 µL: ± 1%; ± 0.2 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.03 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.03 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
10 µL: ± 5%; ± 0.5 µL 20 µL: ± 2.5%; ± 0.5 µL 100 µL: ± 1%; ± 1 µL 200 µL: ± 0.6%; ± 1.2 µL |
15 µL: ± 5%; ± 0.75 µL 30 µL: ± 2.5%; ± 0.75 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 3%; ± 0.9 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 3%; ± 0.9 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
50 µL: ± 6%; ± 3 µL 100 µL: ± 3%; ± 3 µL 500 µL: ± 1%; ± 5 µL 1000 µL: ± 0.6%; ± 6 µL |
50 µL: ± 8%; ± 4 µL 120.0 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
50 µL: ± 8%; ± 4 µL 120.0 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
125 µL: ± 5%; ± 6.25 µL 250 µL: ± 4.8%; ± 12 µL 1250 µL: ± 0.8%; ± 10 µL 2500 µL: ± 0.6%; ± 15 µL |
250 µL: ± 4.8%; ± 12 µL 500 µL: ± 2.4%; ± 12 µL 2500 µL: ± 1.2%; ± 30 µL 5000 µL: ± 0.6%; ± 30 µL |
500 µL: ± 6%; ± 30 µL 1000 µL: ± 3%; ± 30 µL 5000 µL: ± 0.8%; ± 40 µL 10000 µL: ± 0.6%; ± 60 µL |
10 µL: ± 1.2%; ± 0.12 µL | 10 µL: ± 1.2%; ± 0.12 µL | 20 µL: ± 0.8%; ± 0.16 µL | 20 µL: ± 1%; ± 0.2 µL | 25 µL: ± 1%; ± 0.25 µL | 50 µL: ± 0.7%; ± 0.35 µL | 100 µL: ± 0.6%; ± 0.6 µL | 200 µL: ± 0.6%; ± 1.2 µL | 200 µL: ± 0.6%; ± 1.2 µL | 250 µL: ± 0.6%; ± 1.5 µL | 500 µL: ± 0.6%; ± 3 µL | 1000 µL: ± 0.6%; ± 6 µL |
Autoclavable | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Consumables | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | only epT.I.P.S. 384 | only epT.I.P.S. 384 | epT.I.P.S.® | epT.I.P.S.® | only epT.I.P.S. 384 | only epT.I.P.S. 384 | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® |
Open system (third party consumables) | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Delivery content | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x2), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x3), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x2), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x3), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x2), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking clip (to prevent spring action) (x3), O-ring tool | Pipette, epT.I.P.S.® Box 2.0 pipette tips, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Unlocking tool, O-ring tool | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Unlocking tool, O-ring tool | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Protection filter (x10), Pipette wrench | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Protection filter (x10), Pipette wrench | Pipette, epT.I.P.S.® pipette tips sample bag, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Protection filter (x10), Pipette wrench | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Operating manual, Certificate, Adjustment tool (Allen key with blue handle), Adjustment seal for temporary adjustment (x5), Grease for pipettes, Locking ring (to prevent spring action) |
- Forward pipetting
- Reverse pipetting
- Removal of supernatants
- Sample mixing
- Phase extraction
- Filling of plates, gels, and reaction vessels
- Mechanical air-cushion pipette with standard 3-button operation (one operating element for volume selection, one for pipetting, and one for tip ejection)
- Ideal for accurate, easy, and ergonomic manual pipetting of aqueous solutions
- Feel the difference in weight and pipetting forces: Designed according to the Eppendorf PhysioCare Concept® principles
- Benefit from one of the lowest operating and tip ejection forces on the pipette market, helping to reduce hand and arm strain
- Enjoy minimal tip attachment forces due to a spring-loaded tip cone (available for all pipettes up to 1 mL)
- Temporarily adjust your pipette in seconds for better accuracy when pipetting challenging liquids like ethanol or when pipetting at high altitudes. Return to factory adjustment without calibration
- Autoclave the entire pipette or only the lower part according to your needs and applications to ensure a proper decontamination
- Premium material ensures a high UV and chemical resistance; special single-channel lower parts for aggressive chemicals available
- Enjoy excellent flexibility and choose among single-channel pipettes in fixed or variable volume as well as 8-, 12-, 16- and 24-channel pipettes
- ACT®-labeled single-channel pipettes and epT.I.P.S.® pipette tips help you make an informed choice when it comes to sustainability