Eppendorf Xplorer®/ Eppendorf Xplorer® plus - Electronic Pipette
The Eppendorf Xplorer® (plus) electronic pipettes are available as 1-, 8-, 12-, 16-, 24-channel and adjustable tip spacing variant Move It®
Eppendorf Xplorer® (plus) multi-channel electronic pipettes speed up your applications with microplates
The software of your Eppendorf Xplorer® plus pipette can easily be updated using the Pipette Software Update Tool
ACT label of sustainability certification for Eppendorf Xplorer® plus pipette, 100-1000 µL (blue), single-channel
Episode 3: Electronic Pipettes
Videos not loading, because cookies have been rejected. Change your
Episode 7: Consumables
Videos not loading, because cookies have been rejected. Change your
Pipetting with Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
Automatic Dispensing with Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
Pipetting and Mixing with Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
Reverse Pipetting with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
Sequential Dispensing with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
Multi-aspiration with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
Custom Protocols with Eppendorf Xplorer® plus Pipettes
Videos not loading, because cookies have been rejected. Change your
Temporary Adjustment of Eppendorf Xplorer® (plus) Pipettes
Videos not loading, because cookies have been rejected. Change your
384. Ready. Set. Pipette!
Videos not loading, because cookies have been rejected. Change your
384 Wells? No problem.
Videos not loading, because cookies have been rejected. Change your
Episode 5: Liquid Types
Videos not loading, because cookies have been rejected. Change your
Episode 6: Maintenance
Videos not loading, because cookies have been rejected. Change your
Episode 2: Multi-Channel Pipettes
Videos not loading, because cookies have been rejected. Change your
Product Information
People who give 100 % every day deserve the best tools and the best laboratory equipment. The Eppendorf Xplorer and Eppendorf Xplorer plus electronic pipettes are single-, 8-, 12-, 16- and 24-channel pipettes designed to aspirate and dispense liquid volumes from 0.5 µL to 10 mL, while eliminating many of the potential error risks associated with manual pipetting. With the Eppendorf Xplorer/Xplorer plus electronic pipette, your work achieves a new level of simplicity, precision and reproducibility.Eppendorf Xplorer® (plus) Electronic Pipette
You will find additional download material at the bottom of this page
Products (38)
Services (58)
Accessories (18)
Spare Parts (40)
38 Products
$ 1,249.00
|
$ 1,022.00
|
$ 2,149.00
|
$ 1,749.00
|
$ 2,652.00
|
$ 2,154.00
|
|
|
$ 2,788.00
|
$ 2,916.00
|
Show more Products
Product Information
Technical Data
Applications
Features
Simple, fast and precise with untiring battery power – You deserve it!
Eppendorf Xplorer and Xplorer plus electronic pipettes are simple, fast and precise with tireless battery power! Achieve more and get better results thanks to the intuitive operating concept and ergonomic design, supported by the Eppendorf PhysioCare Concept®, setting new standards in simplicity, precision and reproducibility. The Xplorer pipettes are the ideal instrument if you need precisely adjustable parameters, reproducible and accurate results while experiencing fatigue-free pipetting and always maintaining full control over pipetting procedures.
Starting in 2023, all Eppendorf Xplorer and Xplorer plus single-channel pipettes are now certified with an ACT® Environmental Impact Factor Label by the non-profit organization My Green Lab®, providing laboratories with a standardized way to assess sustainability standards and make informed purchasing decisions for environmentally-friendly suppliers.
Discover the exciting extras of the Eppendorf Xplorer plus electronic pipette variants
Eppendorf Xplorer plus is an expanded pipette version that offers exciting extras such as additional operating modes, individual fixed volume settings and programming to make work much easier and faster. Eppendorf Xplorer plus is the perfect motorized pipette choice for all users who simply need advanced speed, safety and reliability every day. Additionally, the expanded Xplorer plus version is available as 16- or 24-channel pipette and as Move It adjustable tip spacing pipette in different volume and channel variants.
Why should I consider using an electronic pipette in the lab?
Compared to mechanical pipettes, electronic pipettes have a number of advantages in many applications. The most important benefits of using an electronic pipette are: Better ergonomics by requiring almost no operating forces, a higher precision and reproducibility and an additional efficiency gain due to various operating modes (such as e.g. pipetting and dispensing with only one tool). Furthermore, electronic instruments are the basis for new, digital and connected pipetting solutions supporting you with choosing settings for different liquid types, collaborating across the lab or documenting steps. With the Eppendorf Pipette Software Update Tool you can easily update your electronic pipette and stay up to date with the latest software improvements and new features! Learn more at Eppendorf's dedicated microsite about electronic pipetting.
Every electronic pipetting activity under control - all the time
All information on the digital pipette display is clearly readable, regardless of your hand position or work position. The optimally angled high-resolution display with a controllable brightness setting guarantees a comfortable work environment.
How to use Eppendorf Xplorer electronic pipettes?
Smart pipette operation with a unique multi-functional rocker gives you precise control over liquid aspiration and dispensing. Simply press the rocker up to aspirate liquids and down to dispense liquids. You can also use the rocker to skip or repeat the blow-out process and even stop the aspiration or dispensing process altogether: just press the rocker down while aspirating or up while dispensing to stop the piston movement. Learn more with our video tutorials!
Operating modes
• Automatic dispensing
• Dispensing
• Pipetting
• Pipetting and mixing
• Manual pipetting
• Multiple aspiration (Xplorer plus only)
• Diluting (Xplorer plus only)
• Sequential pipetting (Xplorer plus only)
• Sequential dispensing (Xplorer plus only)
• Reverse pipetting (Xplorer plus only)
Additional features
• 9 menu languages
• History function saves the 10 last used dispensing settings
• Pre-programmed adjustment for epT.I.P.S.® Long elongated tips
• Individual programming (only in Xplorer plus variants)
• Setting of fixed volumes (only in Xplorer plus variants)
• Password protection (only in Xplorer plus variants)
• Service interval warning (only in Xplorer plus variants)
High performance meets renowned Eppendorf ergonomics
Never feel the strain of hard work thanks to excellent ergonomics implemented according to the criteria of the Eppendorf PhysioCare Concept. The perfect balance and hand rest of the Eppendorf Xplorer electronic pipettes guarantee a low-impact position and means for relaxation between pipetting. The handle and size of the control buttons feature a user-friendly design, irrespective of your hand size. Because your performance is the most valuable resource, we have significantly reduced the weight and required operating force of the Eppendorf Xplorer pipettes.
Ergonomics at Eppendorf - A history of practiced innovation
The spring-loaded tip cone and SoftEject features significantly reduce the force needed to attach and eject tips with Eppendorf Xplorer pipettes. Operating forces can be reduced even further by combining the Xplorer plus 16- and 24- channel pipettes with epT.I.P.S. 384 pipette tips with SoftAttach technology.
Spring-loaded tip cones secure reliable tip fit and effortless attachment
Spring-loaded tip cones are available in all Eppendorf pipettes up to 1,000 µL (except Move It® 300 µL models) to save you time and energy. With haptic feedback, all it takes is one gentle push-down for easy tip attachment. The spring limits the attachment forces and at the same time guarantees a reproducible and safe tip fit. This clever design provides increased user-to-user reproducibility and more consistent results between different lab members.
SoftEject technology reduces tip ejection forces by 50 %
All non-adjustable multi-channel pipettes from Eppendorf use the innovative SoftEject technology to ensure that during each single tip ejection stroke, the outside tips eject before the inside tips. This is not noticeable to the user but reduces tip ejection forces by 50 %. You just lightly press the ejection button once and the tips are automatically ejected in succession.
Speed up your workflows with electronic multi-channel pipettes
Do you need to easily and quickly fill a 24-, 96- or even 384-well microplate? With the efficient Eppendorf Xplorer/Xplorer plus 8-, 12-, 16- and 24-channel as well as Xplorer plus Move It adjustable tip spacing pipettes, you can perform high volume precision work faster. The spring-loaded tip cones help you to load multi-channel tips quickly and securely without a need for rocking. Get extremely consistent sample pickup across all channels and maximize user-to-user reproducibility for more consistent results among members of the lab.
96-well plates
Easily fill 96-well plates with Xplorer or Xplorer plus 8- or 12-channel pipettes featuring a cone distance of 9 mm. The 1,200 µL volume variant is ideal for filling deepwell plates.
👉 Choose epT.I.P.S. pipette tips for 9 mm spacing
Choose Xplorer plus 16- or 24-channel pipettes or our Xplorer plus Move It adjustable pipette variants with 20 µL and 100 µL featuring a (min.) cone distance of 4.5 mm for applications involving 384-well plates. Fill a complete row or column to start 16 or 24 reactions simultaneously in just one step.
👉 Choose epT.I.P.S. 384 pipette tips for 4.5 mm spacing
Fast and efficient pipetting into 384-well plates
Do you need an efficient manual pipetting method for 384-well plate applications? The electronic Eppendorf Xplorer plus 16- and 24- channel pipettes make working with 384-well plates convenient, ergonomic and safe.
Your benefits:
• Tedious alternate well pipetting with 8- or 12-channel pipettes is a thing of the past
• Processing one 384-well plate instead of four 96-well plates improves pipetting efficiency since the number of pipetting steps is reduced by 50 %
• Start 16 or 24 reactions simultaneously for equal starting conditions
• Avoid accidental well misidentification and repeating of experiments
• epT.I.P.S. 384 pipette tips are designed in perfect harmony with these microliter pipettes
epT.I.P.S. 384 with SoftAttach technology for 16- and 24-channel pipettes
For the first time, pipette tips are equipped with elastic forming groves. They allow the tips to stretch as much as the shape of the tip cone predefines. Meanwhile, the tip attachment and ejection forces are greatly reduced. With this latest expression of the Eppendorf PhysioCare Concept, this system enables a perfect tip seal while operating forces are reduced to a minimum.
Your benefits:
• Reliable tip fit and tightness
• Smooth and even tip attachment
• Tip attachment forces reduced by 40 % per cone compared to 8- and 12-channel pipettes
• Reduced ejection forces
• Perfect tip alignment due to extraordinary coaxiality for safe plate maneuvering and liquid transfer
• Extremely fine tip shape to perfectly hit all 384 wells
Disposal of packaging and the pipette at the end of its lifecycle
The packaging of Eppendorf Xplorer electronic pipettes contains different materials, including cardboard and plastic foil. Our Xplorer packaging cardboard material consists of approx. 92 % recycling material. Please support the global sustainability initiative of recycling valuable raw material by collecting the cardboard and disposing of it in the appropriate collection container at your organization. In respect to the wrapping foils made of LD-PE, we recommend to select a dedicated recycling partner where PE material can be recycled.
Eppendorf liquid handling instruments are designed for many years of use – should the need arise to dispose of your electronic pipette however, please note that it may potentially be contaminated and includes electronic components and a rechargeable battery. Please contact your local biosafety officer and/or your local waste management for requirements and best practices concerning electronic and lab waste. You may use the Eppendorf Decontamination Certificate as guidance regarding possible documentation requirements.
Read More
Read Less
Specifications | Eppendorf Xplorer® plus - 4861000708 | Eppendorf Xplorer® - 4861000015 | Eppendorf Xplorer® plus - 4861000767 | Eppendorf Xplorer® - 4861000104 | Eppendorf Xplorer® plus - 4861000775 | Eppendorf Xplorer® - 4861000112 | Eppendorf Xplorer® plus - 4861000710 | Eppendorf Xplorer® - 4861000017 | Eppendorf Xplorer® plus - 4861000778 | Eppendorf Xplorer® plus - 4861000779 | Eppendorf Xplorer® plus - 4861000716 | Eppendorf Xplorer® - 4861000023 | Eppendorf Xplorer® plus - 4861000783 | Eppendorf Xplorer® - 4861000120 | Eppendorf Xplorer® plus - 4861000791 | Eppendorf Xplorer® - 4861000139 | Eppendorf Xplorer® plus - 4861000792 | Eppendorf Xplorer® plus - 4861000793 | Eppendorf Xplorer® plus - 4861000720 | Eppendorf Xplorer® - 4861000027 | Eppendorf Xplorer® plus - 4861000724 | Eppendorf Xplorer® - 4861000031 | Eppendorf Xplorer® plus - 4861000805 | Eppendorf Xplorer® - 4861000147 | Eppendorf Xplorer® plus - 4861000813 | Eppendorf Xplorer® - 4861000155 | Eppendorf Xplorer® plus - 4861000732 | Eppendorf Xplorer® - 4861000040 | Eppendorf Xplorer® plus - 4861000821 | Eppendorf Xplorer® - 4861000163 | Eppendorf Xplorer® plus - 4861000830 | Eppendorf Xplorer® - 4861000171 | Eppendorf Xplorer® plus - 4861000736 | Eppendorf Xplorer® - 4861000044 | Eppendorf Xplorer® plus - 4861000740 | Eppendorf Xplorer® - 4861000058 | Eppendorf Xplorer® plus - 4861000759 | Eppendorf Xplorer® - 4861000066 |
---|
ACT label | yes | yes | − | − | − | − | yes | yes | − | − | yes | yes | − | − | − | − | − | − | yes | yes | yes | yes | − | − | − | − | yes | yes | − | − | − | − | yes | yes | yes | yes | yes | yes |
Product type | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes | Pipettes |
Pipetting type | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system | Air-cushion system |
Number of channels | 1-channel | 1-channel | 8-channel | 8-channel | 12-channel | 12-channel | 1-channel | 1-channel | 16-channel | 24-channel | 1-channel | 1-channel | 8-channel | 8-channel | 12-channel | 12-channel | 16-channel | 24-channel | 1-channel | 1-channel | 1-channel | 1-channel | 8-channel | 8-channel | 12-channel | 12-channel | 1-channel | 1-channel | 8-channel | 8-channel | 12-channel | 12-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel | 1-channel |
Volume range | 0.5 – 10 µL | 0.5 – 10 µL | 0.5 – 10 µL | 0.5 – 10 µL | 0.5 – 10 µL | 0.5 – 10 µL | 1 – 20 µL | 1 – 20 µL | 1 – 20 µL | 1 – 20 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 5 – 100 µL | 10 – 200 µL | 10 – 200 µL | 15 – 300 µL | 15 – 300 µL | 15 – 300 µL | 15 – 300 µL | 15 – 300 µL | 15 – 300 µL | 50 – 1,000 µL | 50 – 1,000 µL | 50 – 1,200 µL | 50 – 1,200 µL | 50 – 1,200 µL | 50 – 1,200 µL | 0.1 – 2.5 mL | 0.1 – 2.5 mL | 0.2 – 5 mL | 0.2 – 5 mL | 0.5 – 10 mL | 0.5 – 10 mL |
Color code | medium gray | medium gray | medium gray | medium gray | medium gray | medium gray | light gray | light gray | light pink | light pink | yellow | yellow | yellow | yellow | yellow | yellow | light yellow | light yellow | yellow | yellow | orange | orange | orange | orange | orange | orange | blue | blue | green | green | green | green | red | red | violet | violet | turquoise | turquoise |
Volume increment | 0.01 µL | 0.01 µL | 0.01 µL | 0.01 µL | 0.01 µL | 0.01 µL | 0.02 µL | 0.02 µL | 0.02 µL | 0.02 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.1 µL | 0.2 µL | 0.2 µL | 0.2 µL | 0.2 µL | 0.2 µL | 0.2 µL | 0.2 µL | 0.2 µL | 1 µL | 1 µL | 1 µL | 1 µL | 1 µL | 1 µL | 2 µL | 2 µL | 5 µL | 5 µL | 10 µL | 10 µL |
Operating mode | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic | electronic |
Pipette Manager enabled | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Display languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages | 9 languages |
Spring-loaded tip cone | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | no | no | no | no | no | no | no | no | no | no |
Random measurement error |
0.5 µL: ± 3%; ± 0.015 µL 1 µL: ± 1.8%; ± 0.018 µL 5 µL: ± 0.8%; ± 0.04 µL 10 µL: ± 0.4%; ± 0.04 µL |
0.5 µL: ± 3%; ± 0.015 µL 1 µL: ± 1.8%; ± 0.0018 µL 5 µL: ± 0.8%; ± 0.04 µL 10 µL: ± 0.4%; ± 0.04 µL |
0.5 µL: ± 6%; ± 0.03 µL 1 µL: ± 3%; ± 0.03 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 0.8%; ± 0.08 µL |
0.5 µL: ± 6%; ± 0.03 µL 1 µL: ± 3%; ± 0.03 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 0.8%; ± 0.08 µL |
0.5 µL: ± 6%; ± 0.03 µL 1 µL: ± 3%; ± 0.03 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 0.8%; ± 0.08 µL |
0.5 µL: ± 6%; ± 0.03 µL 1 µL: ± 3%; ± 0.03 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 0.8%; ± 0.08 µL |
1 µL: ± 3%; ± 0.03 µL 2 µL: ± 1.5%; ± 0.03 µL 10 µL: ± 0.6%; ± 0.06 µL 20 µL: ± 0.3%; ± 0.06 µL |
1 µL: ± 3%; ± 0.03 µL 2 µL: ± 1.5%; ± 0.03 µL 10 µL: ± 0.6%; ± 0.06 µL 20 µL: ± 0.3%; ± 0.06 µL |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 8%; ± 0.08 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 2%; ± 0.2 µL 20 µL: ± 1%; ± 0.2 µL |
5 µL: ± 2%; ± 0.1 µL 10 µL: ± 1%; ± 0.1 µL 50 µL: ± 0.3%; ± 0.15 µL 100 µL: ± 0.2%; ± 0.2 µL |
5 µL: ± 2%; ± 0.01 µL 10 µL: ± 1%; ± 0.1 µL 50 µL: ± 0.3%; ± 0.15 µL 100 µL: ± 0.2%; ± 0.2 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.25%; ± 0.25 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.25%; ± 0.25 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.25%; ± 0.25 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.25%; ± 0.25 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 0.8%; ± 0.4 µL 100 µL: ± 0.6%; ± 0.6 µL |
10 µL: ± 1.4%; ± 0.14 µL 20 µL: ± 0.7%; ± 0.14 µL 100 µL: ± 0.3%; ± 0.3 µL 200 µL: ± 0.2%; ± 0.4 µL |
10 µL: ± 1.4%; ± 0.14 µL 20 µL: ± 0.7%; ± 0.14 µL 100 µL: ± 0.3%; ± 0.3 µL 200 µL: ± 0.2%; ± 0.4 µL |
15 µL: ± 1.4%; ± 0.21 µL 30 µL: ± 0.7%; ± 0.21 µL 150 µL: ± 0.3%; ± 0.45 µL 300 µL: ± 0.2%; ± 0.6 µL |
15 µL: ± 1.4%; ± 0.21 µL 30 µL: ± 0.7%; ± 0.21 µL 150 µL: ± 0.3%; ± 0.45 µL 300 µL: ± 0.2%; ± 0.6 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.25%; ± 0.75 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0%; ± 0.75 µL 300 µL: ± 0.25%; ± 0.75 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.25%; ± 0.75 µL |
15 µL: ± 2%; ± 0.3 µL 30 µL: ± 1%; ± 0.3 µL 150 µL: ± 0.5%; ± 0.75 µL 300 µL: ± 0.25%; ± 0.75 µL |
50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.6%; ± 0.6 µL 500 µL: ± 0.2%; ± 1 µL 1000 µL: ± 0.2%; ± 2 µL |
50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.6%; ± 0.6 µL 500 µL: ± 0.2%; ± 1 µL 1000 µL: ± 0.2%; ± 2 µL |
50 µL: ± 1.2%; ± 0.6 µL 120 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
50 µL: ± 1.2%; ± 0.6 µL 120 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
50 µL: ± 1.2%; ± 0.6 µL 120 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
50 µL: ± 1.2%; ± 0.6 µL 120 µL: ± 0.9%; ± 1.08 µL 600 µL: ± 0.4%; ± 2.4 µL 1200 µL: ± 0.3%; ± 3.6 µL |
100 µL: ± 1.4%; ± 1.75 µL 250 µL: ± 1.2%; ± 3 µL 1250 µL: ± 0.2%; ± 2.5 µL 2500 µL: ± 0.2%; ± 5 µL |
100 µL: ± 1.4%; ± 1.75 µL 250 µL: ± 1.2%; ± 3 µL 1250 µL: ± 0.2%; ± 2.5 µL 2500 µL: ± 0.2%; ± 5 µL |
250 µL: ± 1.2%; ± 3 µL 500 µL: ± 0.6%; ± 3 µL 2500 µL: ± 0.25%; ± 6.25 µL 5000 µL: ± 0.15%; ± 7.5 µL |
250 µL: ± 1.2%; ± 3 µL 500 µL: ± 0.6%; ± 3 µL 2500 µL: ± 0.25%; ± 6.25 µL 5000 µL: ± 0.15%; ± 7.5 µL |
500 µL: ± 1.2%; ± 6 µL 1000 µL: ± 0.6%; ± 6 µL 5000 µL: ± 0.2%; ± 10 µL 10000 µL: ± 0.15%; ± 15 µL |
500 µL: ± 1.2%; ± 6 µL 1000 µL: ± 0.6%; ± 6 µL 5000 µL: ± 0.2%; ± 10 µL 10000 µL: ± 0.15%; ± 15 µL |
Systematic measurement error |
0.5 µL: ± 6%; ± 0.03 µL 1 µL: ± 2.5%; ± 0.025 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 1%; ± 0.1 µL |
0.5 µL: ± 6%; ± 0.03 µL 1 µL: ± 2.5%; ± 0.025 µL 5 µL: ± 1.5%; ± 0.075 µL 10 µL: ± 1%; ± 0.1 µL |
0.5 µL: ± 10%; ± 0.05 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 3%; ± 0.15 µL 10 µL: ± 2%; ± 0.2 µL |
0.5 µL: ± 10%; ± 0.05 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 3%; ± 0.15 µL 10 µL: ± 2%; ± 0.2 µL |
0.5 µL: ± 10%; ± 0.05 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 3%; ± 0.15 µL 10 µL: ± 2%; ± 0.2 µL |
0.5 µL: ± 10%; ± 0.05 µL 1 µL: ± 5%; ± 0.05 µL 5 µL: ± 3%; ± 0.15 µL 10 µL: ± 2%; ± 0.2 µL |
1 µL: ± 4%; ± 0.2 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 1.2%; ± 0.12 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 10%; ± 0.1 µL 2 µL: ± 5%; ± 0.1 µL 10 µL: ± 1.2%; ± 0.12 µL 20 µL: ± 1%; ± 0.2 µL |
1 µL: ± 12%; ± 0.12 µL 2 µL: ± 8%; ± 0.16 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
1 µL: ± 12%; ± 0.12 µL 2 µL: ± 8%; ± 0.16 µL 10 µL: ± 4%; ± 0.4 µL 20 µL: ± 2%; ± 0.4 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 4%; ± 0.2 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 1%; ± 0.05 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 2%; ± 0.2 µL 50 µL: ± 1%; ± 0.5 µL 100 µL: ± 0.8%; ± 0.8 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
5 µL: ± 6%; ± 0.3 µL 10 µL: ± 3%; ± 0.3 µL 50 µL: ± 1.2%; ± 0.6 µL 100 µL: ± 1%; ± 1 µL |
10 µL: ± 5%; ± 0.5 µL 20 µL: ± 2.5%; ± 0.5 µL 100 µL: ± 1%; ± 1.0 µL 200 µL: ± 0.6%; ± 1.2 µL |
10 µL: ± 5%; ± 0.5 µL 20 µL: ± 2.5%; ± 0.5 µL 100 µL: ± 1%; ± 1.0 µL 200 µL: ± 0.6%; ± 1.2 µL |
15 µL: ± 5%; ± 0.75 µL 30 µL: ± 2.5%; ± 0.5 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 5%; ± 0.75 µL 30 µL: ± 2.5%; ± 0.75 µL 150 µL: ± 1%; ± 1 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 2.5%; ± 0.75 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 2.5%; ± 0.75 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 2.5%; ± 0.75 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
15 µL: ± 6%; ± 0.9 µL 30 µL: ± 2.5%; ± 0.75 µL 150 µL: ± 1%; ± 1.5 µL 300 µL: ± 0.6%; ± 1.8 µL |
50 µL: ± 6%; ± 3 µL 100 µL: ± 3%; ± 3 µL 500 µL: ± 1%; ± 5 µL 1000 µL: ± 0.6%; ± 6 µL |
50 µL: ± 6%; ± 3 µL 100 µL: ± 3%; ± 3 µL 500 µL: ± 1%; ± 5 µL 1000 µL: ± 0.6%; ± 6 µL |
50 µL: ± 8%; ± 4 µL 120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
50 µL: ± 8%; ± 4 µL 120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
50 µL: ± 8%; ± 4 µL 120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
50 µL: ± 8%; ± 4 µL 120 µL: ± 6%; ± 7.2 µL 600 µL: ± 2.7%; ± 16.2 µL 1200 µL: ± 1.2%; ± 14.4 µL |
100 µL: ± 5%; ± 6.25 µL 250 µL: ± 4.8%; ± 12 µL 1250 µL: ± 0.8%; ± 10 µL 2500 µL: ± 0.6%; ± 15 µL |
100 µL: ± 5%; ± 6.25 µL 250 µL: ± 4.8%; ± 12 µL 1250 µL: ± 0.8%; ± 10 µL 2500 µL: ± 0.6%; ± 15 µL |
250 µL: ± 4.8%; ± 12 µL 500 µL: ± 3%; ± 15 µL 2500 µL: ± 1.2%; ± 30 µL 5000 µL: ± 0.6%; ± 30 µL |
250 µL: ± 4.8%; ± 13 µL 500 µL: ± 3%; ± 15 µL 2500 µL: ± 1.2%; ± 30 µL 5000 µL: ± 0.6%; ± 30 µL |
500 µL: ± 6%; ± 30 µL 1000 µL: ± 3%; ± 30 µL 5000 µL: ± 0.8%; ± 40 µL 10000 µL: ± 0.6%; ± 60 µL |
500 µL: ± 6%; ± 30 µL 1000 µL: ± 3%; ± 30 µL 5000 µL: ± 0.8%; ± 40 µL 10000 µL: ± 0.6%; ± 60 µL |
Autoclavable | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) | yes (lower part) |
Power supply | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz | 100 – 240 V ±10 %, 50 – 60 Hz |
Battery type | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer | Rechargeable lithium polymer |
Consumables | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | only epT.I.P.S. 384 | only epT.I.P.S. 384 | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | only epT.I.P.S. 384 | only epT.I.P.S. 384 | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® | epT.I.P.S.® |
Open system (third party consumables) | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes | yes |
Delivery content | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking clip to prevent spring action (x2) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking clip to prevent spring action (x2) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking clip to prevent spring action (x3) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking clip to prevent spring action (x3) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x2) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x2) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x3) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x3) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x2) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x2) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x3) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, O-ring tool, Locking clip to prevent spring action (x3) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Locking ring (to prevent spring action) | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Unlocking tool, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Unlocking tool, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Unlocking tool, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Unlocking tool, O-ring tool | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Filter sleeve, Protection filter (x10), Pipette wrench | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Filter sleeve, Protection filter (x10), Pipette wrench | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Filter sleeve, Protection filter (x10), Pipette wrench | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Filter sleeve, Protection filter (x10), Pipette wrench | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Filter sleeve, Protection filter (x10), Pipette wrench | Pipette, Mains/power supply with plug adapters, Operating manual, Short instructions, Certificate, Grease for pipettes, Filter sleeve, Protection filter (x10), Pipette wrench |
- Automated pipetting of liquids (Pip) for forward pipetting
- Manual pipetting (Man) for volume determination
- Pipetting and mixing (P/M) for automated mixing of samples
- Dispensing (Dis) for manual filling of plates, gels, and reaction vessels
- Automatic dispensing (Ads) for automated filling of plates, gels, and reaction vessels
- Multi aspiration (Spc): Pooling supernatants from different vessels1)
- Sequential dispensing and pipetting (Spc) for user-defined volume steps1)
- Reverse pipetting (Spc) for non-aqueous solutions1)
- Diluting (Spc) for preparation of dilution series1)
- Fix volume (Fix): Save up to 10 volumes for ease of operation1)
- Electronic air-cushion pipette reaching new levels of simplicity, precision and reproducibility
- Intuitive handling via multi-function rocker with »up is up« (aspiration) and »down is down« (dispensing) logic and selection dial to access all pipetting modes
- Self-explanatory color display without cluttered submenus and with ergonomic viewing angle for optimal readability in every position
- Spring-loaded tip cone in all Xplorer and Xplorer plus pipettes up to 1,000 µL reduces tip attachment and ejection forces
- Powerful rechargeable battery for up to 8 hours use & work can continue while charging via power socket
- Pre-programmed and individual adjustment to external conditions (e.g. geographic height, liquids with high density, elongated tips)
- Autoclavable lower parts for easy decontamination (all models, incl. Move It®)
- 9 display languages: Chinese, Dutch, English, French, German, Italian, Japanese, Portuguese and Spanish
- Xplorer plus only: Individual programming, fixed volume settings, password protection, additional applications, display of service intervals
- ACT®-labeled single-channel pipettes and epT.I.P.S.® pipette tips help you make an informed choice when it comes to sustainability