epMotion® and its dispensing tools are precision instruments. As such, they should be regularly maintained and calibrated which will help
ensure continuing high accuracy, precision and reproducibility. With our epMotion maintenance and calibration plan options we help you maintain premium performance of your epMotion over an extended period of time? Our Qualification Services include all function tests, calibration and adjustment services needed for Installation and Operational Qualification (IQ/OQ) of your instrument?
Calibration of the dispensing tools are based on ISO 8655 supporting your GLP documentation.
Preventive Maintenance
Global epMotion® Service Agreements from cost-efficient to all-inclusive care packages for easier service process, maximized uptime, and peace of mind!
Read more
Read less
Our comprehensive service agreements
- "AdvancedCare" includes a full annual preventive maintenance service program for assured instrument reliability and uptime; 20 % discount on parts, labor and travel; 10 % discount on additional services (e.g. IQ/OQ) during the agreement period
- "PremiumCare" includes a full annual preventive maintenance service program for assured instrument reliability and uptime; unlimited travel, spare parts and labor on repairs included in the agreement; 10 % discount on additional services (e.g. IQ/OQ) during the agreement period
Read more
Read less
Our preventive maintenance only service
- "Preventive Maintenance" includes all preventive maintenance services to keep the instrument in accordance with the manufacturer specifications
Read more
Read less
Calibration Services
Qualification Services
epMotion®-Service Agreements
Service Agreement Ordering Information | AdvancedCare For assured instrument reliability and uptime | PremiumCare For assured instrument reliability, uptime and financial plannability |
epMotion® 5070 | ||
epMotion® 5073 | ||
epMotion® 5075 | ||
epMotion® 96 | ||
Includes: | ||
Full preventive maintenance | 1/year | 1/year |
Software update (during annual maintenance, if applicable) | ||
Priority Support* | ||
Discount on parts, labor, travel | 20 % | included |
Parts, labor & travel included | - | |
Discount on additional services (e.g. IQ/OQ) | 10 % | 10 % |
Read more
Read less
Attn: This table lists only the most important service operations by plan. The provided service report will show the complete service operations performed.
Info: Our service offers may differ by country. Please contact your local service representative for more information.
Read more
Read less
epMotion® 96 Preventive Maintenance Services
Ordering Information | Preventive Maintenance |
epMotion® 96 | |
Checks and Maintenance: | |
Cleaning | |
Lubrication of dispensing head | |
Checking and exchaning of 96 O-rings from cones | |
Software/firmware update if applicable | |
Verification (Calibration) | |
Leak Test (50 µL + 300 µL) | |
Gravimetric Test systematic error (50 µL + 300 µL) | |
Photometric Test - random error (2 volumes) | |
Documentation | |
Check List provided | |
Dated service sticker to confirm Eppendorf service | |
Calibration Report |
Read more
Read less
epMotion® Preventive Maintenance Services
Ordering Information | Preventive Maintenance |
epMotion® 5070 | |
epMotion® 5073 | |
epMotion® 5075 | |
Cleaning and Maintenance | |
Cleaning of housing/accessories | |
Checking epMotion® for external visible damages | |
Exchange of CAN bus cables/O-rings of dispensing tools | |
Software update* | |
Functional Check | |
Instrument set-up, initial operation, instruction of user | |
Tip ejector, level sensor and carrier | |
Barcode Reader with epBlueTM ID* | |
Thermal modules* and vacuum chamber* | |
TMX module*/TMX module w. Magnetic Finger module* | |
UV light/ CleanCap (HEPA Filter)* | |
Memory | |
Evaluation of stored data | |
Verification | |
Calibration/adjustment of level sensor and carrier | |
Calibration/adjustment of vacuum chamber* | |
Verification of operating parameters according to specifications | |
Calibration/Adjustment of Thermal modules | |
Calibration/Adjustment of Eppendorf ThermoMixer Module | |
Calibration/Adjustment of Magnetic finger module | |
Documentation | |
Check List provided | |
Dated service sticker to confirm Eppendorf service |
Read more
Read less
Attn: This table lists only the most important service operations by plan. The provided service report will show the complete service operations performed.
Info: Our service offers may differ by country. Please contact your local service representative for more information.
Read more
Read less
epMotion® Calibration Services and Other Services
Ordering Information | |
1-channel dispensing tool calibration – 10 measurements per test volume (min, mid, max) including Preventive Maintenance | |
8-channel dispensing tool calibration – 10 measurements per test volume (min, mid, max) including Preventive Maintenance | |
1-channel dispensing tool calibration – 10 measurements per test volume (min, mid, max) without Preventive Maintenance | |
8-channel dispensing tool calibration – 10 measurements per test volume (min, mid, max) without Preventive Maintenance | |
UV lamp exchange | |
epMotion® 5070 installation | |
epMotion® 5073 installation | |
epMotion® 5075 installation | |
epMotion® 96 installation | |
GxP 1-channel dispensing tool calibration – 10 measurements per test volume (min, mid, max) with preventive maintenance as left and as found | |
GxP 8-channel dispensing tool calibration – 10 measurements per test volume (min, mid, max) with preventive maintenance as left and as found |