MENU
US | USD
US | USD
-
- All Centrifuges
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifuge Consumables
- Centrifuge Tubes
- Centrifuge Plates
- Device Management Software
- Sample and Information Management
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Pipette Tips
- Bottle-Top Dispensers
- Pipette Controllers
- Dispenser & Pipette Accessories
- Automated Pipetting
- Automation Consumables
- Automation Accessories
- Liquid Handler & Pipette Services
Sorry, we couldn't find anything on our website containing your search term.
Sorry, we couldn't find anything on our website containing your search term.
Temperatures for PCR: How to Select Optimal Over- and Undershoot
Lab Academy
- Molecular Biology
- Amplification & PCR
- Reproducibility
- Quality
- Accuracy
- PCR Cyclers
- Essay
Temperature overshoot and undershoot is a necessary part of temperature cycling in PCR because it allows the whole reaction liquid in the PCR vessel to quickly reach the desired temperature. Therefore, when deciding how much to overshoot and undershoot in your PCR temperature cycles, this naturally means that the critical dependent factor is the reaction volume involved.
Too high or too low temperatures for PCR will have adverse effects on your results. When you have too high overshoot, especially for PCR denaturation temperatures, you run the risk of killing off some enzyme activity (Figure 1B: Thermal cycler B with overshoot of more than 10°C). Such reduction in enzyme half-life (especially when it happens repetitively at every PCR temperature cycle) can decrease the total PCR yield.
Similarly, when you have a “high” undershoot (large dip in temperatures for PCR), especially when applied to going down from denaturation step to annealing step, it is effectively lowering the stringency of specific primer annealing. For example, if you set annealing to 65°C, but it stays at 5°C below that temperature for many seconds due to undershoot, it can increase the chances of non-specific amplification during that period of time (Figure 1).
Similarly, when you have a “high” undershoot (large dip in temperatures for PCR), especially when applied to going down from denaturation step to annealing step, it is effectively lowering the stringency of specific primer annealing. For example, if you set annealing to 65°C, but it stays at 5°C below that temperature for many seconds due to undershoot, it can increase the chances of non-specific amplification during that period of time (Figure 1).
Read more
Figure 1: Temperature profiles of Eppendorf Mastercycler and Thermal cycler B. Their respective over-shoot PCR denaturation temperatures, and undershoot algorithms for annealing temperatures are shown.
Top tip: Look at your thermal cycler settings!
Some thermal cycler manufacturers set a high degree of over-/undershoot in their temperatures for PCR profile, while others use sample volume prediction algorithms to change the degree of over/under-shoot required. However, this neglects the characteristics of different DNA templates. DNA templates with higher GC-content require higher energy for breaking the bonds and hence require a higher PCR denaturation temperature at the same sample volume.
How to optimize the degree of over- and undershooting in your PCR temperature cycles
The proprietary temperature control algorithm in Eppendorf thermocyclers, including Mastercycler® X50 (Figure 2), helps ensure that the degree of overshoot and undershoot is within the optimal range of the set point temperature. This allows fast heat transfer without the associated deleterious effects.
Some thermal cycler manufacturers set a high degree of over-/undershoot in their temperatures for PCR profile, while others use sample volume prediction algorithms to change the degree of over/under-shoot required. However, this neglects the characteristics of different DNA templates. DNA templates with higher GC-content require higher energy for breaking the bonds and hence require a higher PCR denaturation temperature at the same sample volume.
How to optimize the degree of over- and undershooting in your PCR temperature cycles
The proprietary temperature control algorithm in Eppendorf thermocyclers, including Mastercycler® X50 (Figure 2), helps ensure that the degree of overshoot and undershoot is within the optimal range of the set point temperature. This allows fast heat transfer without the associated deleterious effects.
Read more
Figure 2: The four temperature control modes of Mastercycler® X50 caters for different reaction volumes and/or GC-content of the DNA template and the algorithm uniquely match the suitable degree of overshoot and undershoot necessary for the entire liquid volume to reach set point temperature homogenously in the shortest time.
In other words, optimal temperature overshoot is good for fast transfer of energy from thermal block to sample in reaction vessel, leading to fast PCR completion and optimal yield and specificity. Too high overshoot or undershoot will reduce PCR yield and increase the risk of mispriming.
Want more tips to help you optimize your PCRs?
When setting up your PCRs, we understand how there are many different elements to consider! Learn how you can take your experiments to the next level by exploring our lab academy. You can also visit our Eppendorf Youtube channel for further PCR tips and tricks.
Want more tips to help you optimize your PCRs?
When setting up your PCRs, we understand how there are many different elements to consider! Learn how you can take your experiments to the next level by exploring our lab academy. You can also visit our Eppendorf Youtube channel for further PCR tips and tricks.
Read more
Videos not loading, because cookies have been rejected. Change your