MENU
US | USD
US | USD
-
- All Centrifuges
- Benchtop Centrifuges
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Refrigerated Centrifuges
- Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- IVD Products
- High-Speed and Ultracentrifuge Consumables
- Accessories
- Centrifuge Tubes
- Centrifuge Plates
- Device Management Software
- Sample and Information Management
- VisioNize Devices
- GLP Products China
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- All Micropipettes
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Pipette Tips
- Bottle-Top Dispensers
- Pipette Controllers
- Dispenser & Pipette Accessories
- Automated Pipetting
- Automation Consumables
- Automation Accessories
- Liquid Handler & Pipette Services
- IVD Products
Sorry, we couldn't find anything on our website containing your search term.
Sorry, we couldn't find anything on our website containing your search term.
Magnetic bead nucleic acid extraction & NGS library prep: Why automated pipetting improves results
Lab Academy
- Molecular Biology
- Liquid Handling
- Automation
- Liquid Handling Workstations
- Essay
Handling magnetic beads is a critical step within NGS library preparation or nucleic acid purification. There is a lot to be considered that this process does not mutate into a strenuous and error-prone tightrope act. Wouldn't it be nice if there was some relief – topped with an improved precision, accuracy and reproducibility? Read why automated pipetting makes your bead-based cleanup become a walk in the park!
“Bead” It! – What are magnetic beads used for?
The use of magnetic beads is a fast, efficient and convenient method for the extraction and cleanup of nucleic acids from complex mixtures. During magnetic bead nucleic acid extraction, the beads bind genomic DNA, plasmids, RNA or mitochondrial DNA reversibly and can be safely immobilized and separated by a strong magnet.
Magnetic bead nucleic acid extraction offers several benefits, including its high yield, excellent purity, and affordability. The technique is very “gentle”, because it involves no centrifugation steps that may cause breaking of nucleic acids due to shear forces. Being easy to execute by simply putting a magnet to the vessel, magnetic bead nucleic acid extraction is easily scalable to sample numbers and volumes – an optimal prerequisite for high-throughput applications. Quite logical, that the bead-based cleanup is part of nearly every NGS library preparation and sample prep for NGS workflow to select a specific fragment size. Also, nucleic acid extraction or purification (NAP) utilizes the advantages of bead-based cleanups. Magnetic bead technologies are also used in magnetic beads protein purification workflows, demonstrating their versatility beyond nucleic acid applications.
Up to 2.000 manual pipetting steps are involved in NGS library prep!
However, especially when processing large numbers of samples, this technique demands a lot. The laborious procedure burdens you with a tremendous number of pipetting steps in exhaustive long and complex protocols. An NGS library preparation for 48 samples means pipetting up to 2000 x with 5 h hands on time. NAP of 24 samples strikes with 500 x pipetting and 2 h hands-on time.
Do you work manually in 96-well-format? Then you have to cope with small, nearly invisible pellets, especially when located in the center of the plate. What you cannot see, you cannot react to. To deliver the permanent concentration the process requires, you almost need the qualities of a machine. Thus, this manual “Sisyphus work” bears a high susceptibility to errors and a high risk of losing beads.
Bead carryover is another famous manual pipetting issue, as they can interfere with downstream applications. Inter-user and inter-run variabilities as well as liquid transfer with manual pipettes can impair precision, accuracy and reproducibility.
After all, failed experiments are not an option as they lead to loss of valuable sample, reagents, consumables, time and money.
Critical magnetic bead-handling during NGS library prep
The handling of magnetic beads is one of the most critical steps during preparation of a high-quality NGS library. Bead-based cleanups appear several times for removal of impurities, buffer and enzymes from previous enzymatic reactions.
For the recovery of a reproducible DNA fragment size, you have to stick meticulously to the bead-to-DNA volume ratio and a thorough bead resuspension. A proper consumable-to-magnet fit during separation is vital for a high-quality cleanup. The magnet has to be strong enough to avoid loss of beads. Optimal ethanol removal is essential for final elution of DNA fragments and to avoid inhibitory effects in downstream reactions. NGS beads in viscous PEG-solution require the right pipetting technique and equipment to be pipetted precisely.
These requirements make automated solutions particularly valuable for sample preparation NGS workflows.
Read more
The benefits of an automated bead clean-up
Pipetting robots take all those considerations off your shoulders. What an enormous relief! Magnetic bead-based protocols like NGS library preparation, magnetic bead nucleic acid extraction, or NAP become a walk in the park:1. Reduced hands-on time. Complex pipetting-intensive protocols become ready-to-run with minimal interventions. For example: Preparing an NGS library prep out of total RNA requires 2 days manual work of repetitive pipetting and outstandingly high concentration. With an automated liquid handler, you can reduce your hands-on time to something between 30 min and 2 h and as little as 10 to 50 pipetting steps (depending on your sample number and used protocol). For NAP you can reduce your hands-on time down to 10-15 minutes and reduce the manual pipetting steps to a bare minimum for a 2 h run. Imagine what you could do with the time you gained!
Read more
Overview of genomic workflows with pipetting steps and hands on time.
2. No more loss of beads or carryover. Concentrated manual “Sisyphus Work” with invisible pellets in tiny wells belongs to the past. Honestly, the pipetting robot can do it better and never gets tired! And you have practically no bead carryover as beads are transferred safely and precisely, improving overall beads purification performance.
3. Perfect bead handling for NGS-library prep. Your pipetting robot is perfectly equipped and educated for the recovery of a reproducible DNA fragment size. The volume ratio of bead-to-DNA will be kept, beads will be thoroughly resuspended, a strong magnet will recover beads without loss, the proper consumable-to-magnet fit during separation ensures a high-quality cleanup. Ethanol will remove optimally so you avoid inhibitory downstream effects. Beads in PEG-solutions will be pipetted precisely.
4. Pre-optimized bead-based protocols for NGS library prep and NAP. Modern liquid handlers support automated library prep workflows. For customization, you can break down complex workflows into single steps with simple commands which you can easily align in the software.
5. Consistent precision and accuracy. No person-to-person and day-to-day variability and no errors associated with manual pipetting keep precision and accuracy and pave the way for reproducible results.
6. Scale your throughput up. Process up to 96 samples with ease and without nervous breakdowns.
7. Improved user safety. Less manual pipetting, less strain on muscles and joints.
3. Perfect bead handling for NGS-library prep. Your pipetting robot is perfectly equipped and educated for the recovery of a reproducible DNA fragment size. The volume ratio of bead-to-DNA will be kept, beads will be thoroughly resuspended, a strong magnet will recover beads without loss, the proper consumable-to-magnet fit during separation ensures a high-quality cleanup. Ethanol will remove optimally so you avoid inhibitory downstream effects. Beads in PEG-solutions will be pipetted precisely.
4. Pre-optimized bead-based protocols for NGS library prep and NAP. Modern liquid handlers support automated library prep workflows. For customization, you can break down complex workflows into single steps with simple commands which you can easily align in the software.
5. Consistent precision and accuracy. No person-to-person and day-to-day variability and no errors associated with manual pipetting keep precision and accuracy and pave the way for reproducible results.
6. Scale your throughput up. Process up to 96 samples with ease and without nervous breakdowns.
7. Improved user safety. Less manual pipetting, less strain on muscles and joints.
Read more
Which pipetting robot should you choose for your bead-based cleanup?
Read more
Several pipetting robot models are available. You can choose from smart benchtop versions up to large high-throughput machines depending on your sample numbers, workflow complexity, and future automation plans.
For labs performing routine magnetic bead-based nucleic acid extraction, NGS library prep, or other sample preparation NGS workflows, a compact liquid handler is often an ideal starting point. Systems such as the Eppendorf epMotion® 5073 are designed for applications including NGS library preparation, magnetic nucleic acid extraction, PCR setup, dilution series, and normalization while requiring only a small laboratory footprint.
If your lab processes larger batches of samples, the Eppendorf epMotion® 5075 offers increased deck capacity and can automate workflows ranging from NGS library preparation and nucleic acid extraction to solid-phase extraction and magnetic bead cleanups for up to 96 samples. epMotion 5075 is also ideal for automated protein purification workflows.
For plate-based workflows, the Eppendorf epMotion® 96 Flex provides fast 96-channel liquid handling for 96- and 384-well plates. Its design is particularly well suited to repetitive bead cleanup steps, where precision, and reproducibility are essential.
The good news is that bead-based workflows are among the most automation-friendly laboratory processes. Whether you are looking to streamline a few weekly NGS cleanups or fully implement library prep automation, there is an automated liquid handling solution that can help reduce hands-on time, improve reproducibility, and minimize the risk of bead loss or carryover.
For labs performing routine magnetic bead-based nucleic acid extraction, NGS library prep, or other sample preparation NGS workflows, a compact liquid handler is often an ideal starting point. Systems such as the Eppendorf epMotion® 5073 are designed for applications including NGS library preparation, magnetic nucleic acid extraction, PCR setup, dilution series, and normalization while requiring only a small laboratory footprint.
If your lab processes larger batches of samples, the Eppendorf epMotion® 5075 offers increased deck capacity and can automate workflows ranging from NGS library preparation and nucleic acid extraction to solid-phase extraction and magnetic bead cleanups for up to 96 samples. epMotion 5075 is also ideal for automated protein purification workflows.
For plate-based workflows, the Eppendorf epMotion® 96 Flex provides fast 96-channel liquid handling for 96- and 384-well plates. Its design is particularly well suited to repetitive bead cleanup steps, where precision, and reproducibility are essential.
The good news is that bead-based workflows are among the most automation-friendly laboratory processes. Whether you are looking to streamline a few weekly NGS cleanups or fully implement library prep automation, there is an automated liquid handling solution that can help reduce hands-on time, improve reproducibility, and minimize the risk of bead loss or carryover.
Read more
Excellent work needs excellent equipment
The best painter cannot paint with a bad brush! And so, does a pipetting robot. Stability comes first! Warping microtiter plates after heating is an absolute no-go. A perfect fit between vessel and magnet is crucial for NGS to have an optimal purification. Otherwise, the plate has to be exchanged after heating, which means sample loss. Microtiter plates with smallest dead volume minimize liquid loss. Take care that your consumables are clean and leachable-free.
Read more
Videos not loading, because cookies have been rejected. Change your
Read more