- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
-
- All Centrifuges
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifuge Consumables
- Centrifuge Tubes
- Centrifuge Plates
- Device Management Software
- Sample and Information Management
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Automated Pipetting
- Bottle-Top Dispensers
- Pipette Controllers
- Pipette Tips
- Automation Consumables
- Dispenser & Pipette Accessories
- Automation Accessories
- Dispenser & Pipette Services
Viral Vector Process Development

Read more
Upstream bioprocess development for viral vector production
Read more
Plasmid production
In the context of viral vector production, plasmids can be adapted to contain the instructions for producing viruses with specific genomes. Through standard plasmid cloning, viruses can therefore be engineered to contain important genes for either gene therapy or vaccination purposes. Viral vectors can be used as a powerful tool for the delivery of this genetic information into mammalian cells. During the plasmid production stage, plasmids are either constructed in the laboratory or selected from existing stock. The type and number of plasmids you require will depend on the viral vector you choose to use and whether you intend to use transient or stable cell lines. Learn more about plasmid production in our webinar!

Cell expansion and virus production
Read more
Cultivation of adherent cells
Growing adherent cells relies on a growth support matrix. Conventionally, 2D culture systems like flasks and dishes have been used, but as technology has evolved, cultivation in bioreactors provides an alternative option that exploits the benefits they offer in terms of process control and scalability. The use of microcarrier-based culture systems and packed-bed bioreactors filled with Fibra-Cel® Disks are options for cultivating adherent cells in bioreactors.

Fibra-Cel® Disks
Read more
Microcarrier-based cell culture systems
Read more
Plasmid transfection, viral vector production, and harvest
Read more
Learn more about transient and stable transfection
Read more
Read more
Read more
Bioprocessing for AAV vector production
Cells will need to be harvested and the viral vectors isolated for characterization and quantification. An important part of this process is determining the ratio of viral vectors with genomes to those without, known as the full/empty ratio. This can be done using methods including ELISA, electron microscopy, analytical ultracentrifugation (AUC), and high-pressure liquid chromatography (HPLC), each of which has benefits and limitations of its own. For information on AAV vector production workflow in a bioreactor, check out this application note!

Eppendorf upstream bioprocessing solutions for cell culture
Read more
Small scale bioreactor systems
The DASbox® Mini Bioreactor System and DASGIP® Parallel Bioreactor Systems for cell culture applications are well suited for process development and downscaling approaches.
- Working volume range: 100 mL to 1.5 L
- Parallel processing of up to 24 bioreactors
- Compatible with glass bioreactors and BioBLU® Single-Use Bioreactors
- Suitable for suspension cell culture and cell culture on microcarriers

Bench scale bioreactor systems
The bench scale bioreactor systems BioFlo® 120 , BioFlo® 320 , and SciVario® twin facilitate process development and scale-up
- Working volume range: 200 mL to 40 L
- Compatible with glass bioreactors and BioBLU® Single-Use Bioreactors
- Suitable for suspension cell culture and cell culture on microcarriers
- Compatible with packed-bed bioreactors filled with Fibra-Cel® Disks

Large scale bioreactor systems
For cell cultivation at large scale Eppendorf offers the BioFlo® 720 bioreactor control system.
- Offers scalability from 50 L to 2000 L
- Compatible with the BioBLU® 50c Single-Use Bioreactor
- Compatible with Thermo Scientific® HyPerforma® Single-Use Bioreactors

Contact us
Read more