- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
-
- All Centrifuges
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifuge Consumables
- Centrifuge Tubes
- Centrifuge Plates
- Device Management Software
- Sample and Information Management
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Automated Pipetting
- Bottle-Top Dispensers
- Pipette Controllers
- Pipette Tips
- Automation Consumables
- Dispenser & Pipette Accessories
- Automation Accessories
- Dispenser & Pipette Services
Bioprocess Optimization

Improve reproducibility
Improve yield
Reducing batch variability and improving yield
Read more
How can bioprocess reproducibility be improved?
Read more
Fine control of process conditions
Fine-tuning the control of your bioprocess is critical to ensure quality, yield, and batch consistency of the product produced. You can automatically gain information about your process by implementing Process Analytical Technology (PAT). PAT can provide real-time monitoring of critical process parameters (CPPs), such as pH, DO, temperature, cell density, cell viability, nutrient concentrations, by-product concentrations, and help to keep these within a defined range. When incorporated into bioreactor control systems, PAT can be used to acquire data in real-time and use it to leverage feedback loops, for automated, in-process parameter control. For example, it is possible to automate culture feeding based upon the glucose concentration in the medium. By automating bioprocess control, stress on the cells can be reduced significantly, and form a sound foundation for optimal performance.

Robust calibration of sensors
Read more
Interested in how to increase the reproducibility of cell culture bioprocesses? Check out our e-book .

Ensuring consistent cell quality in bioreactor culture
- Monitor cell growth in your shake flask culture – Take note of your flask culture data, including cell density and metabolites. Creating a growth curve can be an effective way to see if your culture is on track.
- Optimize your passage schedule – Ensure that you split your cells at the optimal time point in their growth phase. Too frequent passaging can hinder cell density, while too infrequent will cause metabolite build up and affect viability.
- Keep your flask in optimum conditions – Ensure that flasks are kept in an incubator with optimized temperature, plus CO2, oxygen, and moisture levels. Make sure that flasks spend minimal time outside the incubator for monitoring/passage.
- Keep track of pH levels – Try and keep the pH level in the flask and in the bioreactor medium at a standard level to avoid pH shock. In-flask pH monitoring systems is useful for this.
Read more
Want to learn more about inoculum optimization in a cell culture scale-up workflow? Check out our application note.

How can bioprocess yield and productivity be improved?
Read more
Choose the best process mode for you
Read more
Solutions for bioprocess optimization
Read more
Eppendorf has a range of bioprocess control solutions to help you with optimizing your process, including but not limited to:
- DASbox® Mini Bioreactor System : Designed for small working volumes and parallel experimentation, it can boost your bioprocessing research and early process development.
- DASware® control bioprocess control software : Enables bioprocess monitoring and control and the integration of analytical devices to your bioreactor system. Along with the DASware® software suite, this is a valuable tool for experimental design.