Centrifuge Solution for Plasmid construction, Sequencing preparation and Humanization
Target antigen production, sequencing sample preparation, and antibody humanization involve a great deal of repetitive molecular biology handling steps. This includes spin column based MiniPrep kits for nucleic acid purification, gel extraction, and PCR clean-up. Each protocol has multiple centrifugation steps interrupted by pipetting and vessel changes. Microcentrifuges have entered a new generation, with the completely newly developed Centrifuge 5425 in combination with kit rotor specifically designed for 1.5/2.0 mL spin column kits.
Key benefits
Read more
INCREASED EFFICIENCY
- Rotary knobs control for faster changes of speed and time.
- Fast access to your most frequently used settings with three custom program buttons.
- One push short-spin key for quick centrifugation – no need to hold key all the while.
Read more
IMPROVED SAMPLE SAFETY
- Reduced risk of cross-contamination in spin column applications due to extended rim that serves as reinforcement for open tube caps during centrifugation and protects caps from shearing off.
- Automatic lid opening at the end of the run prevents sample warming and allows easy access to samples.
- Integration of incubation steps via timer function for increased reproducibility.
Read more
BETTER ERGONOMICS
- Short runs up to 12 minutes are whisper quiet at an average of 45 dB(A). This is sufficient for centrifugation steps of most routinely used DNA/RNA purification kits. During longer runs the cooling fan works at full capacity.
- QuickLock rotors close with only 1/4 of a turn. This not only saves you time during every day use, it also takes repetitive stress off your wrist.
- Soft-touch one-finger lid closure for ergonomic lid locking.
Read more
Components
Centrifuge 5425
- Whisper quiet 24-place standard microcentrifuge with outstanding feature set for broad range of applications, non-refrigerated.
- Extended rotor program (e.g. 5.0 mL rotor, swing-bucket rotor for PCR strips).
- Max. capacity: 10 × 5.0 mL vessels.
Rotor FA-18x2-Kit
- Fixed-angle rotor for molecular biology applications in 18 × 1.5/2.0 mL tubes or spin columns.
- Aerosol-tight with Eppendorf QuickLock lid.
- Max. speed: 18,565 × g (15,060 rpm).
Read more
Recommended Consumables
Key Methods | Consumables | Advantages |
|
|
|
Read more
Learn about all Centrifuge Solutions for mAb
Download our new poster to find all details you need to know about our centrifuge solutions.Read more
Request your individual support
Request your individual support
Your own dedicated expert assists you in finding the perfect match for your specific mAb workflow. Get your individual consultation!
Read more