MENU
US | USD
US | USD
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- All Micropipettes
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Bottle-Top Dispensers
- Pipette Controllers
- Dispenser & Pipette Accessories
- Automated Pipetting
- Automation Consumables
- Automation Accessories
- Liquid Handler & Pipette Services
Sorry, we couldn't find anything on our website containing your search term.
Sorry, we couldn't find anything on our website containing your search term.
- Home
- Lab Academy
- Life Science
- Cell Biology
- Cell seeding protocol – Guide on how to seed cells correctly
Cell seeding protocol – Guide on how to seed cells correctly
Lab Academy
- Cell Biology
- Cell Therapy
- Reproducibility
- Liquid Handling
- Pipettes
- Pipette Tips
- Essay
Cell seeding is usually the first protocol step and a standard procedure in cell-based experiments. A correct and standardized cell seeding protocol is a critical factor for reproducible experimental results. The main challenge in this step is to achieve and maintain comparable cell numbers in all repeated experiments.
This article was published first in "Inside Cell Culture" , the monthly newsletter for cell culture professionals. Find more interesting articles about CO2 incubators on our page "FAQs and material on CO2 incubators" .
Dr. Jessica Wagener, Application Specialist Cell Handling at Eppendorf
Cell seeding is usually the first protocol step and a standard procedure in cell-based experiments. A correct and standardized cell seeding protocol is a critical factor for reproducible experimental results. The main challenge in this step is to achieve and maintain comparable cell numbers in all repeated experiments. Variations in seeding cell numbers and the formation of air bubbles during seeding will increase standard deviations, making your results less reliable. Therefore, several factors need to be considered when establishing a solid cell seeding protocol in your lab.
When you seed your cells, from a 15 mL tube into a multi-well plate, for example, it will take some time until you have filled all the wells. No matter if you use a single-channel or a multi-channel pipette in your cell seeding protocol, the longer the process takes, the more cells will sediment in the tube. So, without mixing the cell suspension in the tube or reservoir, you will get varying cell numbers from one well to another (Image 1).
Dr. Jessica Wagener, Application Specialist Cell Handling at Eppendorf
Contents
- The impact of standardized cell seeding protocol
- The time factor and cell sedimentation
- Video: Correct pipetting technique
- Air bubble formation
- Video: How to avoid air bubble formation in cell seeding
- Homogeneous cell adhesion
- Cell density dependent behavior
Why is cell seeding a critical step in all cell culture experiments?
Cell seeding is usually the first protocol step and a standard procedure in cell-based experiments. A correct and standardized cell seeding protocol is a critical factor for reproducible experimental results. The main challenge in this step is to achieve and maintain comparable cell numbers in all repeated experiments. Variations in seeding cell numbers and the formation of air bubbles during seeding will increase standard deviations, making your results less reliable. Therefore, several factors need to be considered when establishing a solid cell seeding protocol in your lab.
The time factor in cell seeding protocols
When you seed your cells, from a 15 mL tube into a multi-well plate, for example, it will take some time until you have filled all the wells. No matter if you use a single-channel or a multi-channel pipette in your cell seeding protocol, the longer the process takes, the more cells will sediment in the tube. So, without mixing the cell suspension in the tube or reservoir, you will get varying cell numbers from one well to another (Image 1). Read more
Image 1: Cell sedimentation is a critical factor to consider in every cell seeding protocol. Cells sediment in the vessel within minutes – the longer the cells seeding process takes, the lower the number of cells in the supernatant.
The process of cell sedimentation is quite fast, within minutes. To avoid this effect, you need to resuspend or mix the cells before seeding to agitate them and generate a homogeneous solution. This way, an equal number of cells per well is ensured.
Video: Correct pipetting technique in a cell seeding protocol
Read more
Videos not loading, because cookies have been rejected. Change your
Air bubble formation during cell seeding
Cell culture media tend to foam due to the high protein content of supplemented serum. Air bubbles can hinder cell attachment during seeding and therefore create well-to-well variations of cell numbers (Image 2). Especially in smaller plate formats like 96- and 384-well plates, air bubbles can have a big impact due to the small growth area per well. So, although resuspending or mixing is necessary, you should not overdo it and avoid too much pipetting to reduce air bubble formation. Gentle pipetting also reduces shear forces and stress for your cells – a critical part of every cell seeding protocol.Read more
Image 2: Air bubbles formed during cell seeding can hinder cell attachment. Note how the cells located nearby the air bubble cannot attach properly to the vessel bottom
Video: How to avoid air bubble formation in cell seeding
Read more
Videos not loading, because cookies have been rejected. Change your
Homogeneous cell adhesion
In addition to an equal cell number, a homogeneous cell distribution on the growth surface of a culture vessel can have an impact on your experimental outcome. Different techniques are common, usually passed from more experienced scientists in a lab to their trainees. But what is the best method to evenly distribute the cells on the growth surface? In Image 3, you can see a comparison of different techniques.On the left, you see what happens if you just prefill the vessel with cell culture medium, add the cells, and call it a day. As a result, the cells mainly adhere in the middle of the vessel. To achieve an equal cell distribution, some people use a “figure-eight” movement, while others prefer a cross-like movement of the plate or dish. Both techniques lead to a better distribution of the cells. However, the smaller the vessel diameter, the less movement of the liquid you have, leading to an uneven distribution of cells. An effective way to circumvent this effect during cell seeding is to first dilute the cell suspension to the desired concentration in a tube or reservoir (mastermix) and then pipette the final volume to the culture vessel in one step.
Read more
Image 3: Various methods with various efficiencies exist, all striving to ensure homogeneous cell adhesion after transfer into the culture vessel. The use of a mastermix with the final cell concentration is recommended. Cells were fixed and stained with crystal violet.
Does cell density matter?
The uniformity of cell distribution can have a significant impact on your experiment. Of course, there are cell types that tend to grow in colonies rather than forming a homogenous monolayer. But in general, the cells should spread as uniformly as possible over the entire growth surface of the culture vessel. One example showing the direct impact of cell distribution and cellular responses is the transfection efficiency (image 4 and 5).Read more
Image 4: GFP-transfected cells in various areas of a cell culture dish after two cell seeding methods.
As shown in the graph, the highest ratio of transfected vs. non-transfected cells is achieved with medium cell density. In addition, a uniform transfection efficiency will result from an evenly distributed cell layer generated by applying the mastermix-approach. Considering both factors in a cell seeding protocol will optimize your transfection efficiency and lower the standard deviation.
Read more
Image 5: The transfection efficiency depends on cell density. The optimal transfection rate and uniform distribution is achieved at medium cell density combined with a mastermix approach.