MENU
US | USD
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- Stem Cell Community Day 2025
- Analytica Lab India 2025
- JASIS 2025
- GSCN 2025
US | USD
-
- All Centrifuges
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifuge Consumables
- Centrifuge Tubes
- Centrifuge Plates
- Device Management Software
- Sample and Information Management
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Automated Pipetting
- Bottle-Top Dispensers
- Pipette Controllers
- Pipette Tips
- Automation Consumables
- Dispenser & Pipette Accessories
- Automation Accessories
- Dispenser & Pipette Services
Sorry, we couldn't find anything on our website containing your search term.

How Drying Tubes Protect Your Solutions
Lab Academy
- Cell Biology
- Contamination
- Safety & Biosafety
- Pipetting & Dispensing
- Dispensers
- Essay
Fuming acids are characterized by gas rising off the surface. These acids are made of the maximum concentration of gas dissolved in water, such as 37 % hydrochloric acid and 65 % nitric acid. Such acids need protection from dilution by surrounding air humidity. Humidity traps are often built into the lids of bottles containing these chemicals. However, if you want to dispense these liquids by using a bottletop dispenser, care must be taken not to introduce air humidity into the bottle and the system. A drying tube is the ideal accessory for this application. It is simply screwed to the back of the bottletop dispenser and filled with a moisture absorber e.g., silica gel. The air needed for proper operation of the bottletop dispenser is then filtered by the drying tube and only a very low amount of humidity enters the bottle. The acids are protected from dilution and your experiment is protected from failure by incorrect acid concentration.
When working with alkaline solutions, the formation of carbonates inside the liquid and the bottletop dispenser may lead to problems. When using a drying tube, for example filled with sodium hydroxide pills, formation of carbonates is excluded. You will be able to work with the liquid and bottletop dispenser without any issues.
And don’t forget to protect yourself and your colleagues by providing and wearing the appropriate personal protective equipment, such as a lab coat, gloves, and goggles. Additionally, long trousers such as jeans and sturdy shoes should be worn.
When working with alkaline solutions, the formation of carbonates inside the liquid and the bottletop dispenser may lead to problems. When using a drying tube, for example filled with sodium hydroxide pills, formation of carbonates is excluded. You will be able to work with the liquid and bottletop dispenser without any issues.
And don’t forget to protect yourself and your colleagues by providing and wearing the appropriate personal protective equipment, such as a lab coat, gloves, and goggles. Additionally, long trousers such as jeans and sturdy shoes should be worn.