MENU
US | USD
US | USD
-
- All Centrifuges
- Benchtop Centrifuges
- Floor-Standing Centrifuges
- Refrigerated Centrifuges
- Microcentrifuges
- Multipurpose Centrifuges
- High-Speed Centrifuges
- Ultracentrifuges
- Concentrator
- High-Speed and Ultracentrifuge Consumables
- Centrifuge Tubes
- Centrifuge Plates
- Device Management Software
- Sample and Information Management
-
- All Pipettes, Dispensers & Automated Liquid Handlers
- Mechanical Pipettes
- Electronic Pipettes
- Multi-Channel Pipettes
- Positive Displacement Pipettes & Dispensers
- Pipette Tips
- Bottle-Top Dispensers
- Pipette Controllers
- Dispenser & Pipette Accessories
- Automated Pipetting
- Automation Consumables
- Automation Accessories
- Liquid Handler & Pipette Services
Sorry, we couldn't find anything on our website containing your search term.
Sorry, we couldn't find anything on our website containing your search term.
Webinar
Increasing Upstream Bioprocessing Efficiency through Process Analytical Technology
Lab Academy
- Bioprocessing
- Cell Identity
- Bioprocess
- Recorded Webinars
In this webinar we present strategies for in line process analytics that aimed at automated feed control in an upstream bioprocess.
In biologics production, the upstream bioprocess contributes significantly to product quality and manufacturing efficiency. A comprehensive understanding on which process parameters are critical and how they influence process outcome allows the development of tailored control strategies and, as a result, achieving consistent process performance.
Compared to offline measurements in a sample that has been taken from the bioreactor, inline analysis of process parameters reduces the manual workload and facilitates the implementation of automated feedback control loops. While inline analytics of some process parameters, such as temperature, DO, and pH is well established, real-time measurement of others, such as metabolite concentrations or cell viability is not yet routine.
In this webinar we present strategies for in line process analytics that aimed at automated feed control in an upstream bioprocess. Using the example of a Raman analyzer, a glucose analyzer, and an exhaust analyzer we demonstrate, how to achieve seamless sensor integration with the bioprocess control software. In all cases we met the challenge of keeping the glucose concentration stable during the bioprocess run and minimize human intervention.
Key Learning Objectives:
Duration:
35 minutes
Speaker:
Dr. Joerg Schwinde, Eppendorf AG – Bioprocess Center, Juelich, Germany
Fill out the form below to watch the webinar.
Compared to offline measurements in a sample that has been taken from the bioreactor, inline analysis of process parameters reduces the manual workload and facilitates the implementation of automated feedback control loops. While inline analytics of some process parameters, such as temperature, DO, and pH is well established, real-time measurement of others, such as metabolite concentrations or cell viability is not yet routine.
In this webinar we present strategies for in line process analytics that aimed at automated feed control in an upstream bioprocess. Using the example of a Raman analyzer, a glucose analyzer, and an exhaust analyzer we demonstrate, how to achieve seamless sensor integration with the bioprocess control software. In all cases we met the challenge of keeping the glucose concentration stable during the bioprocess run and minimize human intervention.
Key Learning Objectives:
- Get to know, how inline process analytics can improve bioprocess efficiency
- Learn, which bioreactor software features are needed to integrate analyzers and to implement automated feedback control loops
- Benefit from hands-on experience in integrating analyzers to automate culture feeding
Duration:
35 minutes
Speaker:
Dr. Joerg Schwinde, Eppendorf AG – Bioprocess Center, Juelich, Germany
Fill out the form below to watch the webinar.
Read more