15-Aug-2012
Update_Analog
_IO_B.00.zip

Version Analog B.00
Analog I/O software revision B.00 includes the ability to recognize and control up to 8 Analog I/O modules from a single installed version, and addresses previous issues with communication loss.

BioCommand® Batch Control Updates

NOTE: This update is required for any current customer planning to use BioCommand witha BioFlo® 320. The enhancements made to are specific to the TCP/Modbus protocol used in the BioFlo® 320. There is no change to the functionality of BioCommand for all other New Brunswick™ bioprocess equipment.

NOTE: It is recommended that all customers update their software, however, customers running Revision C BioCommand software packages with all other New Brunswick™ bioprocess equipment are not required to install the update.

WARNING: Do not attempt to install this update on BioCommand® Batch Control Plus installations. Database files are not compatible and may result in loss of data. For BioCommand® Batch Control Plus updates, please contact your local sales/service representative.

Date/File/VersionDescription of Changes
5-Jan-2015
BioCommand TT BC Update Version D.zip
Version D
Revision D includes the following enhancements:
• Communication over TCP/Modbus protocol
• Addition of proportional and integral (P&I) values to programming section
• Addition of control mode selection to programming section
• Addition of P&I, deadband, and totalizer values to Batch Summary,    Datalog, and Reports

BioCommand® SFI Updates

Date/File/VersionDescription of Changes
22-May-2013
M1291-1252 
Rev C.00 - Update.zip

Version C
The updated version of BioCommand SFI allows for the correct interperation of values when used with European operating systems while continuing to report values on US operating systems. This improved version also allows BioCommand SFI to be used with up to 2 each New Brunswick S41i CO2 Incubator Shakers.
It trends and archieves critical data including temperature, speed and gas concentration but does not provide batch control.

BioCommand® Track and Trend Updates

NOTE: This update is required for any current customer planning to use BioCommand witha BioFlo® 320. The enhancements made to are specific to the TCP/Modbus protocol used in the BioFlo® 320. There is no change to the functionality of BioCommand for all other New Brunswick™ bioprocess equipment.

NOTE: It is recommended that all customers update their software, however, customers running Revision C BioCommand software packages with all other New Brunswick™ bioprocess equipment are not required to install the update.

WARNING: Do not attempt to install this update on BioCommand® Batch Control Plus installations. Database files are not compatible and may result in loss of data. For BioCommand® Batch Control Plus updates, please contact your local sales/service representative.

Date/File/VersionDescription of Changes
5-Jan-2015
BioCommand TT BC Update Version D.zip
Version D
Revision D includes the following enhancements:
• Communication over TCP/Modbus protocol
• Addition of proportional and integral (P&I) values to programming section
• Addition of control mode selection to programming section
• Addition of P&I, deadband, and totalizer values to Batch Summary, Datalog, and Reports

BioFlo®CelliGen® 115 Updates

Date/File/VersionDescription of Changes

1-April-2015
Update_M1369_5.01.zip
Version 5.01 (E)

Software revision 05.01 incorporates the following solutions/additions to improve the performance of your bioprocess controller:

• Update for Corporate Identity
• Activation of Trending Module

BioFlo® 120 Updates

Date/File/VersionDescription of Changes

07-August-2017
Update_BF120_
02050003.zip

Version 02.05

Software revision 02.05 incorporates the following solutions/additions to improve the performance of your bioprocess controller: 

NOTE: This is a critical software update as IP addressing issues may lead to board failure, requiring board replacement

• Resolves Static IP addressing issues if network settings contains an IPv6 IP address or invalid Netmask.

BioFlo® 310, BioFlo 415 & CelliGen® 310 Updates

Date/File/VersionDescription of Changes
11-Mar-2015
Update_M1297
_12.04.zip

Version 12.04

Software revision 12.04 incorporates the following solutions / additions to improve the performance of your bioprocess controller:

  • Update for Corporate Identity
  • Includes updates from Revision L.02
    • Improved driver installation for RS-232 / USB device for externalscale interface (4 or 8 port)
    • Gas flow scaling has been added to all 3 or 4 gas configuration for CO2 gas
    • IP address function, allowing remote connectivity to RPC controller

BioFlo® 320 Updates

Date/File/VersionDescription of Changes
17-Oct-2018
Update_R320GUI_02060007.zip

Issues fixed in this revision
  • Changed single use warning message to not exceed 10psig, it was 6psig previously
  • Remove Micro/Macro selection from 3c/5c/5p selection
  • Limited NSPluginErr.log file size to 256k, to avoid memory overload

Enhancements done in this revision

  • 10c is added back, it is same as 14c just text change to include vessel selection
  • Software now detects 5SLPM sparge TMFC and assigns limits accordingly
  • New OPC tags are added for Delta-V integration

 

BioFlo® 510 Updates

Date/File/VersionDescription of Changes

15-March-2017

UPDATE_M1361
_02.02.2006.zip

Version 02.02.0006

Software revision 02.02.0006 incorporates the following solutions/additions to improve the performance of your bioprocess system:
• TY-35B Overlay Value was always off (Close) on sterilization mode. This was resolved to allow TY-35B to open when the temperature falls below 121°C

BioFlo® 610 Updates

Date/File/VersionDescription of Changes

25-Jan-2016
Update_M1362_ 02.03.0003.zip

Software revision 02.03 incorporates the following solutions/additions to improve the performance of your bioprocess controller:
• On the sterilize screen, ‘Sparge’ and ‘Overlay’ toggle buttons were changed to be visible to the operator

CelliGen® BLU (1st Generation) Updates

NOTE: This update is specific to 1st generation CelliGen BLU cabinets. Please check the model of your CelliGen BLU cabinet. If your CelliGen BLU model number begins with the prefix "M1363", please follow the steps on this page to complete your update. If your CelliGen BLU model number begins with the prefix "M1374", please see the update CelliGen BLU (2nd Generation)

Date/File/VersionDescription of Changes
8-Apr-2014
M1363_C.00.zip

CelliGen®BLU (first generation only) software revision C.00 provides the following resolutions and/or enhancements:

• Manual gas mixing total percent correction
• Improved RS-232 communication for scale driver
• Implementation of CO2 scaling for dedicated TMFC
• IP Network capability
• Improved storage of optical pH parameters

CelliGen® BLU (2nd Generation) Updates

NOTE: This update is specific to 2nd generation CelliGen BLU cabinets. Please check the model of your CelliGen BLU cabinet. If your CelliGen BLU model number begins with the prefix "M1374", please follow the steps on this page to complete your update. If your CelliGen BLU model number begins with the prefix "M1363", please see the update for CelliGen BLU (1st Generation).

Date/File/VersionDescription of Changes
11-March-2015
UPDATE_M1374_2.02.zip
Version 2.02

Software revision 02.02 incorporates the following solutions / additions to improve the performance of your bioprocess controller:

Update for Corporate Identity

Update default Proportional and Integral values for pH loop

RS-232 OPC Server Updates

Date/File/VersionDescription of Changes
15-May-2013
M1295 RS232 Device Interface Kit Rev B.00 - Update.zip
Version B
Update resolves communication errors with PC COM ports.

ThermoMixer® C, ThermoMixer® F, and ThermoStat® C Updates

Date/File/VersionDescription of Changes
11-Sep-2018
3.0.0 - ThermoMixer Autoupdate.zip