How qPCR Automation Boosts Efficiency While Preventing Cross-Contamination
Lab Academy
- Molecular Biology
- PCR
- Reproducibility
- Automation
- Liquid Handling Workstations
- Essay
Standard PCR combined with fluorescent reporter monitoring, real-time quantitative PCR (qPCR), allows you to amplify, detect, and quantify the targeted molecule in a single step. However, manual qPCR set-up is time-consuming, tedious, and requires a lot of practice, because the most probable source of imprecision is the operator itself.
Automated qPCR setup is an effective way to overcome the issues associated with manual qPCR. In this article, we explore how qPCR automation can improve your workflow efficiency, reduce contamination risks, and deliver reliable, reproducible results for routine and high-throughput qPCR.
A real-world example of qPCR automation
Automated Liquid Handling systems are ideal for reliable and reproducible set-up of sensitive real-time quantitative PCR (qPCR) assays in daily routine, without the risk of cross-contamination. For example, a very sensitive qPCR assay developed for Acinetobacter baumannii has been selected and set-up with epMotion workstations . The high performance of this assay is demonstrated by generating a standard concentration curve of genomic DNA (gDNA).
Read more
How to understand and prevent qPCR contamination
Besides issues with reproducibility, qPCR reactions can also be affected by nucleic acid contamination, leading to false positive results.
The three possible sources of contamination are:
Precautions can be taken to reduce the risk of contamination: uracil DNA glycosylase (UDG) can be used to prevent DNA carryover contamination between reactions, materials can be systematically decontaminated, and separate workstations for each step of the qPCR process can be designated to create an efficient workflow. However, those measures do not eliminate the major cause of false positive results: the accidental contamination with positive samples during Liquid Handling.
Consistent PCR liquid handling practices are essential, particularly when processing large sample numbers. Automated systems help reduce variability introduced by manual pipetting and minimize the risk of sample-to-sample contamination.
The three possible sources of contamination are:
- cross-contamination between samples
- contamination from laboratory equipment
- carryover contamination by amplified products from previous qPCRs.
Precautions can be taken to reduce the risk of contamination: uracil DNA glycosylase (UDG) can be used to prevent DNA carryover contamination between reactions, materials can be systematically decontaminated, and separate workstations for each step of the qPCR process can be designated to create an efficient workflow. However, those measures do not eliminate the major cause of false positive results: the accidental contamination with positive samples during Liquid Handling.
Consistent PCR liquid handling practices are essential, particularly when processing large sample numbers. Automated systems help reduce variability introduced by manual pipetting and minimize the risk of sample-to-sample contamination.
Read more
qPCR contamination troubleshooting: finding the source
Effective qPCR contamination troubleshooting requires identifying the likely source of contamination and implementing controls at every stage of sample preparation and assay setup. Reviewing no-template controls (NTCs), evaluating amplification plots, and monitoring trends between runs can help identify whether contamination originates from reagents, equipment, the laboratory environment, or sample handling procedures.
A common challenge in molecular biology workflows is distinguishing true target amplification from background contamination. For example, genomic DNA contamination qPCR signals can occur when nucleic acid samples are not sufficiently purified or when handling procedures introduce unwanted material into reactions. Establishing standardized workflows and contamination-control measures can help reduce these risks.
Laboratories should also periodically review workspace design, PCR clean-up procedures, and reagent handling practices. While preventing contamination during qPCR setup is the priority, reviewing downstream processes and, where appropriate, a PCR clean-up protocol can provide additional confidence when investigating the root cause of unexpected results. A documented PCR clean-up protocol may also support consistency across operators and experiments.
A common challenge in molecular biology workflows is distinguishing true target amplification from background contamination. For example, genomic DNA contamination qPCR signals can occur when nucleic acid samples are not sufficiently purified or when handling procedures introduce unwanted material into reactions. Establishing standardized workflows and contamination-control measures can help reduce these risks.
Laboratories should also periodically review workspace design, PCR clean-up procedures, and reagent handling practices. While preventing contamination during qPCR setup is the priority, reviewing downstream processes and, where appropriate, a PCR clean-up protocol can provide additional confidence when investigating the root cause of unexpected results. A documented PCR clean-up protocol may also support consistency across operators and experiments.
Read more
The importance of consumables in preventing qPCR contamination
In addition to workflow design and automation, the quality of laboratory consumables plays an important role in preventing qPCR contamination. Eppendorf qPCR consumables , including twin.tec® real-time PCR Plates are designed to support accurate, reliable, and reproducible assay performance. When these consumables are used alongside PCR automation systems, they enable consistent, high-throughput sample handling, with a minimized risk of contamination.
Read more
Demonstrating contamination-free automated qPCR setup
In order to demonstrate that cross-contamination will not occur, an FDA guideline proposes to use high positive samples in series alternating with negative samples. The epMotion was used for a complete qPCR set-up without cross-contamination, 48 high positive samples (containing 105 copies of A. baumanii gDNA) and 48 negative samples (containing water) have been dispensed in the 96-well PCR plate in a chessboard pattern.
Read more
This approach demonstrates the value of automated qPCR setup in applications where assay sensitivity and reproducibility are critical. By automating repetitive pipetting steps, laboratories can reduce contamination risks while maintaining consistent performance across plates and runs.
All negative samples were negative and the complete process is highly reproducible. The mean intra-plate Ct value for the 48 positive samples is very consistent with a coefficient of variation never exceeding 1.5%.
All negative samples were negative and the complete process is highly reproducible. The mean intra-plate Ct value for the 48 positive samples is very consistent with a coefficient of variation never exceeding 1.5%.
Read more
Looking for more information on qPCR automation?
Our Application Note provides more information to help you improve your qPCR automation workflow and support reliable PCR automation processes.
Read more
Automation isn’t just for qPCR!
Automation isn’t just for qPCR – it is a valuable tool for other molecular techniques, including PCR and NGS. As with qPCR setup, using automated liquid handling for PCR streamlines PCR prep activities, helping to standardize workflows while reducing opportunities for operator error. An integrated PCR automation system can support both assay development and high-throughput testing applications, delivering greater efficiency across the lab.
For NGS workflows, automation can reduce hands-on time, improve consistency between runs, and support the production of high-quality sequencing libraries. By automating repetitive liquid handling steps, labs can scale throughput while maintaining reliable and reproducible results.
If you’re unsure which workflows and kits are suitable for Eppendorf automation systems, the epMotion Method Overview lists protocols that have been pre-tested for epMotion automated liquid handling workstations.
For NGS workflows, automation can reduce hands-on time, improve consistency between runs, and support the production of high-quality sequencing libraries. By automating repetitive liquid handling steps, labs can scale throughput while maintaining reliable and reproducible results.
If you’re unsure which workflows and kits are suitable for Eppendorf automation systems, the epMotion Method Overview lists protocols that have been pre-tested for epMotion automated liquid handling workstations.