Software Downloads

Software and Firmware Updates

Software/Firmware revisions are made available at no charge through this web page so that all users can benefit from the latest performance enhancements.
The easy upgrade procedure takes only a few minutes to perform.

Updates for Existing CPUs

New Brunswick S41i CO2 Incubator Shaker Updates
Date/File/VersionDescription of Changes
10-March-2015
M1334 Display Version 1.98.zip
Update adds a reconfirmation screen screen that is displayed when shaker platform is turned off. The screen will disappear after 10 seconds if no action is taken.
6-August-2014
M1334 IO Controller Version 1.40.zip
Internal test function added.
BioFlo® 110 Firmware Updates
Date/File/VersionDescription of Changes
30-Nov-2006
bfver201.zip
Version 2.1
Resolves PCU display issues when switching between different languages. Also improves communication between modules. Use this file only if your BioFlo 110 PCU display is orange and black.
30-Nov-2006
bfver201c.zip
Version 2.1C
Resolves PCU display issues when switching between different languages. Also improves communication between modules. Use this file only if your BioFlo 110 PCU display is blue and white.
BioFlo®/CelliGen® 115 Updates
Date/File/VersionDescription of Changes

1-April-2015
Update_M1369_5.01.zip
Version 5.01 (E)

Software revision 05.01 incorporates the following solutions/additions to improve the performance of your bioprocess controller:

• Update for Corporate Identity
• Activation of Trending Module

BioFlo® 120 Updates
Date/File/VersionDescription of Changes

07-August-2017
Update_BF120_
02050003.zip

Version 02.05

Software revision 02.05 incorporates the following solutions/additions to improve the performance of your bioprocess controller: 

NOTE: This is a critical software update as IP addressing issues may lead to board failure, requiring board replacement

• Resolves Static IP addressing issues if network settings contains an IPv6 IP address or invalid Netmask.

BioFlo® 310, BioFlo 415 & CelliGen® 310 Updates
Date/File/VersionDescription of Changes
11-Mar-2015
Update_M1297
_12.04.zip

Version 12.04

Software revision 12.04 incorporates the following solutions / additions to improve the performance of your bioprocess controller:

  • Update for Corporate Identity
  • Includes updates from Revision L.02
    • Improved driver installation for RS-232 / USB device for externalscale interface (4 or 8 port)
    • Gas flow scaling has been added to all 3 or 4 gas configuration for CO2 gas
    • IP address function, allowing remote connectivity to RPC controller
BioFlo® 320 Updates
Date/File/VersionDescription of Changes

22-March-2017

Update_R320GUI_
02040001.zip

Software revision 02.04 incorporates the following solutions/additions to improve
the performance of your bioprocess controller:

• Resolves system start-up issue due to server, client connectivity
       NOTE: This is a required critical update to resolve the system start up issue.
• Resolves intermittent flow control at low limit (0.04 SLPM) for gas flow loop
• Resolves hardware assignments for gas mixing of O2, N2, CO2

BioFlo® 510 Updates
Date/File/VersionDescription of Changes

15-March-2017

UPDATE_M1361
_02.02.2006.zip

Version 02.02.0006

Software revision 02.02.0006 incorporates the following solutions/additions to improve the performance of your bioprocess system:
• TY-35B Overlay Value was always off (Close) on sterilization mode. This was resolved to allow TY-35B to open when the temperature falls below 121°C

BioFlo® 610 Updates
Date/File/VersionDescription of Changes

25-Jan-2016
Update_M1362_ 02.03.0003.zip

Software revision 02.03 incorporates the following solutions/additions to improve the performance of your bioprocess controller:
• On the sterilize screen, ‘Sparge’ and ‘Overlay’ toggle buttons were changed to be visible to the operator
CelliGen® BLU (1st Generation) Updates

NOTE: This update is specific to 1st generation CelliGen BLU cabinets. Please check the model of your CelliGen BLU cabinet. If your CelliGen BLU model number begins with the prefix "M1363", please follow the steps on this page to complete your update. If your CelliGen BLU model number begins with the prefix "M1374", please see the update CelliGen BLU (2nd Generation)

Date/File/VersionDescription of Changes
8-Apr-2014
M1363_C.00.zip

CelliGen®BLU (first generation only) software revision C.00 provides the following resolutions and/or enhancements:

• Manual gas mixing total percent correction
• Improved RS-232 communication for scale driver
• Implementation of CO2 scaling for dedicated TMFC
• IP Network capability
• Improved storage of optical pH parameters

CelliGen® BLU (2nd Generation) Updates

NOTE: This update is specific to 2nd generation CelliGen BLU cabinets. Please check the model of your CelliGen BLU cabinet. If your CelliGen BLU model number begins with the prefix "M1374", please follow the steps on this page to complete your update. If your CelliGen BLU model number begins with the prefix "M1363", please see the update for CelliGen BLU (1st Generation).

Date/File/VersionDescription of Changes
11-March-2015
UPDATE_M1374_2.02.zip
Version 2.02

Software revision 02.02 incorporates the following solutions / additions to improve the performance of your bioprocess controller:

Update for Corporate Identity

Update default Proportional and Integral values for pH loop

Analog Input/Output Module Updates
Date/File/VersionDescription of Changes
15-Aug-2012
Update_Analog
_IO_B.00.zip

Version Analog B.00
Analog I/O software revision B.00 includes the ability to recognize and control up to 8 Analog I/O modules from a single installed version, and addresses previous issues with communication loss.
BioCommand® SFI Updates
Date/File/VersionDescription of Changes
22-May-2013
M1291-1252
Rev C.00 - Update.zip

Version C
The updated version of BioCommand SFI allows for the correct interperation of values when used with European operating systems while continuing to report values on US operating systems. This improved version also allows BioCommand SFI to be used with up to 2 each New Brunswick S41i CO2 Incubator Shakers.
It trends and archieves critical data including temperature, speed and gas concentration but does not provide batch control.
BioCommand® Track and Trend Updates

NOTE: This update is required for any current customer planning to use BioCommand with
a BioFlo® 320. The enhancements made to are specific to the TCP/Modbus protocol used in the
BioFlo® 320. There is no change to the functionality of BioCommand for all other New Brunswick™ bioprocess equipment.

NOTE: It is recommended that all customers update their software, however, customers running Revision C BioCommand software packages with all other New Brunswick™ bioprocess equipment
are not required to install the update.

Date/File/VersionDescription of Changes
5-Jan-2015
BioCommand TT BC Update Version D.zip
Version D
Revision D includes the following enhancements:
• Communication over TCP/Modbus protocol
• Addition of proportional and integral (P&I) values to programming section
• Addition of control mode selection to programming section
• Addition of P&I, deadband, and totalizer values to Batch Summary, Datalog, and Reports
BioCommand® Batch Control Updates

NOTE: This update is required for any current customer planning to use BioCommand with
a BioFlo® 320. The enhancements made to are specific to the TCP/Modbus protocol used in the
BioFlo® 320. There is no change to the functionality of BioCommand for all other New Brunswick™ bioprocess equipment.

NOTE: It is recommended that all customers update their software, however, customers running Revision C BioCommand software packages with all other New Brunswick™ bioprocess equipment
are not required to install the update.

Date/File/VersionDescription of Changes
5-Jan-2015
BioCommand TT BC Update Version D.zip
Version D
Revision D includes the following enhancements:
• Communication over TCP/Modbus protocol
• Addition of proportional and integral (P&I) values to programming section
• Addition of control mode selection to programming section
• Addition of P&I, deadband, and totalizer values to Batch Summary,    Datalog, and Reports
BioCommand® Plus Software Updates

NOTE: This update is only for BioCommand Plus 3.30 customers. All other versions of BioCommand Software are not compatible with this software update.

To determine which version software you currently have installed:

  • Open your BioCommand software program on your PC.
  • The first screen that comes up identifies both the name (ie. BioCommand Plus) and version number of your software. If you have BioCommand Plus 3.3, proceed with the following update.
Date/File/VersionDescription of Changes
19-July-2006
BioCommandPlus
SP1.zip

Version 3.30
Improves communications and supervisory control to the reactor controllers. Required with the BioFlo 310. Use this file only if your software is BioCommand Plus, version 3.30.
RS-232 OPC Server Updates
Date/File/VersionDescription of Changes
15-May-2013
M1295 RS232 Device Interface Kit Rev B.00 - Update.zip
Version B
Update resolves communication errors with PC COM ports.

Updates for Replacement CPUs

BC Local Initial Load Software

NOTE: This update is only to be used when installing a NEW CPU board!

Date/File/VersionDescription
6-August-2013
BCLOCAL_V234.zip
Version 2.3.4
BC Local software for initial installation.
BioFlo® 310 / 415 & CelliGen® 310 Initial Load Software

NOTE: This update is only to be used when installing a NEW CPU board!

Date/File/VersionDescription
6-August-2013
Update_M1297
_Initial_L.01.zip

Version L.01
BioFlo 310 / 415 & CelliGen 310 software for initial installation.
BioFlo® 510 Initial Load Software

NOTE: This update is only to be used when installing a NEW CPU board!

Date/File/VersionDescription
6-August-2013
UPDATE_M1361
_Initial_A7.zip

Version A7
BioFlo 510 software for initial installation.