MENU
CH | CHF
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- DataHow Symposium 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- LabDays 2025
- ILMAC 2025
- Stem Cell Community Day 2025
- Nordic Life Science Days 2025
- JASIS 2025
-
-
-
-
- Forum Labo 2025
- Advanced Therapies Week (ATW) 2025
- SLAS Europe 2025
- Bioprocessing Summit Europe 2025
- Medlab Middle East 2025
- SLAS International 2025
- Biologics World Nordics 2025
- ASIA LABEX: The Lab Show 2025
- BioProcess International Europe 2025
- ISEV 2025
- Future Labs Live 2025
- DataHow Symposium 2025
- Cell 2025
- ASIA LABEX: The Lab Show 2025
- LabDays 2025
- ILMAC 2025
- Stem Cell Community Day 2025
- Nordic Life Science Days 2025
- JASIS 2025
CH | CHF
-
- Toutes les centrifugeuses
- Centrifugeuses de paillasse
- Centrifugeuses au sol
- Centrifugeuses réfrigérées
- Microcentrifugeuses
- Centrifugeuses multi-fonctions
- Centrifugeuses haute vitesse
- Ultracentrifugeuses
- Concentrateur
- Produits IVD
- High-Speed and Ultracentrifuge Consumables
- Tubes de centrifugeuse
- Plaques de centrifugeuse
- Gestion des appareils
- Gestion des échantillons et des informations
-
- Toutes les pipettes, tous les distributeurs et tous les systèmes automatisés de manipulation de liquides
- Pipettes mécaniques
- Pipettes électroniques
- Pipettes multicanaux
- Distributeurs et pipettes à déplacement positif
- Pointes de pipette
- Distributeurs sur flacon
- Auxiliaires de pipetage
- Accessoires pour pipettes et distributeurs
- Automates de pipetage
- Consommables d’automatisation
- Accessoires d’automatisation
- Services pour pipettes et distributeurs
Sorry, we couldn't find anything on our website containing your search term.
Sorry, we couldn't find anything on our website containing your search term.
Reducing PCR bias for NGS library construction
Lab Academy
- Biologie moléculaire
- Next Generation Sequencing
- Amplification et PCR
- Cyclers PCR
- Test
It has been shown that thermal cyclers with a slow ramp rate can reduce bias during PCR with GC-rich targets during NGS library preparation. But there are also options to optimize your PCR protocol on a fast ramping thermal cycler with simple elongation of certain PCR steps, or adaption of the ramping speed.
Next-generation sequencing library construction includes many steps: e.g., LD-PCR (long-distance PCR, 2 kb in length), then acoustic shearing to the appropriate size and used in a standard Illumina library preparation (involving end-repair and kination, A-tailing and adapter ligation, followed by additional amplification by PCR) [1]. Library preparations can be susceptible to bias resulting from genomes that contain unusually high or low GC content and approaches have been developed to address these situations through careful selection of polymerases for PCR amplification, thermocycling, conditions and buffers [2]. But also, the thermal cycler used influences the PCR result and improvement is possible.
Steep, fast ramp rates have been shown to be inappropriate for amplification of GC rich targets (above 80 % GC). The “steep thermoprofile does not leave sufficient time above a critical threshold temperature” so that “incomplete denaturation and poor amplification” can be the result [2]. There are multiple options to improve your PCR protocol for obtaining better results, such as addition of chemicals, change of polymerase, etc.
What to consider while NGS library preparation
In this article, we highlight three prospects related to thermal cyclers with a fast heating ramp rate to reduce PCR bias when preparing NGS libraries:
1. Optimization of the PCR protocol: Improvement includes elongation of the initial denaturation time and the denaturation time in every cycle by 6-8 times than given in the protocol [2]. But this elongates the whole PCR process and lapses the most obvious advantage of a fast ramping cycler.
2. Adapt the ramping speed: Some thermal cyclers have the option to program a desired ramping speed. Like this it is easy to soften the heating and cooling to reduce bias during PCR.
3. Play with the denaturation temperature: not only elongation of the denaturation step, but also testing different denaturation temperatures can be beneficial for adequate denaturation of GC rich targets and improve the PCR result. This can be done by either programming a gradient step in the denaturation step (if the cycler only offers 1 gradient option), or by programming a gradient in the denaturation and annealing step (if the cycler offers a 2D-gradient). The advantages of a 2D gradient are obvious. Two steps of the PCR protocol can be optimized in one run, while for a thermal cycler that offers only 1 gradient two PCR runs are necessary.
Successful preparation of your NGS library
Overall, it is possible to use a fast ramping thermal cycler for NGS PCR applications, but a slower ramp rate showed beneficial results for GC-rich targets from the start without optimization effort. When it comes to the thermal cycler itself, we recommend using a slower ramping thermal cycler such as the Mastercycler® X40 with a max. of 3.3 °C/s heating ramp rate that can still be reduced if necessary.
1. Steven R. Head,1 H. Kiyomi Komori,2 Sarah A. LaMere,2 Thomas Whisenant,2 Filip Van Nieuwerburgh,3 Daniel R. Salomon,2 and Phillip Ordoukhanian. Library construction for next-generation sequencing: Overviews and challenges. Biotechniques. 2014; 56(2):61
2. Aird D, Ross MG, Chen WS, Danielsson M, Fennell T, Russ C, Jaffe DB, Nusbaum C, Gnirke A. Analyzing and minimizing PCR amplification bias in Illumina sequencing libraries. Genome Biol. 2011;12:R18
Steep, fast ramp rates have been shown to be inappropriate for amplification of GC rich targets (above 80 % GC). The “steep thermoprofile does not leave sufficient time above a critical threshold temperature” so that “incomplete denaturation and poor amplification” can be the result [2]. There are multiple options to improve your PCR protocol for obtaining better results, such as addition of chemicals, change of polymerase, etc.
What to consider while NGS library preparation
In this article, we highlight three prospects related to thermal cyclers with a fast heating ramp rate to reduce PCR bias when preparing NGS libraries:
1. Optimization of the PCR protocol: Improvement includes elongation of the initial denaturation time and the denaturation time in every cycle by 6-8 times than given in the protocol [2]. But this elongates the whole PCR process and lapses the most obvious advantage of a fast ramping cycler.
2. Adapt the ramping speed: Some thermal cyclers have the option to program a desired ramping speed. Like this it is easy to soften the heating and cooling to reduce bias during PCR.
3. Play with the denaturation temperature: not only elongation of the denaturation step, but also testing different denaturation temperatures can be beneficial for adequate denaturation of GC rich targets and improve the PCR result. This can be done by either programming a gradient step in the denaturation step (if the cycler only offers 1 gradient option), or by programming a gradient in the denaturation and annealing step (if the cycler offers a 2D-gradient). The advantages of a 2D gradient are obvious. Two steps of the PCR protocol can be optimized in one run, while for a thermal cycler that offers only 1 gradient two PCR runs are necessary.
Successful preparation of your NGS library
Overall, it is possible to use a fast ramping thermal cycler for NGS PCR applications, but a slower ramp rate showed beneficial results for GC-rich targets from the start without optimization effort. When it comes to the thermal cycler itself, we recommend using a slower ramping thermal cycler such as the Mastercycler® X40 with a max. of 3.3 °C/s heating ramp rate that can still be reduced if necessary.
1. Steven R. Head,1 H. Kiyomi Komori,2 Sarah A. LaMere,2 Thomas Whisenant,2 Filip Van Nieuwerburgh,3 Daniel R. Salomon,2 and Phillip Ordoukhanian. Library construction for next-generation sequencing: Overviews and challenges. Biotechniques. 2014; 56(2):61
2. Aird D, Ross MG, Chen WS, Danielsson M, Fennell T, Russ C, Jaffe DB, Nusbaum C, Gnirke A. Analyzing and minimizing PCR amplification bias in Illumina sequencing libraries. Genome Biol. 2011;12:R18
Lire moins